00193891-0702_AI_LP_Barcode_DE+EN.pdf - 第173页

SIPLACE 2 PCB barcode scanner assembly instructions 10/2009 Edition 2.7 Installing the PCB barcode scanner 173 2.7.3.3 Electrical connection: HS-50 barcode distributor / conveyor control : For the TSP 100 conveyor contro…

100%1 / 272
Plug
2 PCB barcode scanner assembly instructions SIPLACE
2.7 Installing the PCB barcode scanner 10/2009 Edition
172
2
Fig. 2.7 - 4 HS-60 / D4 conveyor control
2
The jumper assignment for the interface (SIPLACE / SMEMA) on the conveyor control must cor-
respond to the current interfaces otherwise the barc
ode data will not be forwarded correctly to the
station software. 2
J1 = SIPLACE/SMEMA upstr
eam station
J2 = SIPLACE/SMEMA downstream station
SIPLACE = setting 1-2; SMEMA setting 2-3. 2
SIPLACE 2 PCB barcode scanner assembly instructions
10/2009 Edition 2.7 Installing the PCB barcode scanner
173
2.7.3.3 Electrical connection: HS-50 barcode distributor / conveyor control
: For the TSP 100 conveyor control, connect the cable (item no.: 03021617-xx).
For the TSP 200, use cable number 03016825-xx (see also the wiring diagram for the HS-50
SC in
Section 2.9).
2
2
2
2
Machines with a dual conveyor will require the 00119330-01 package. This contains a second bar-
code distributor and a second set of cables (see also the wiring diagram for the HS-50 DC in Sec-
tion 2.9). 2
2
: Plug the connecting cables for the barcode scanner into the distributor rail as follows:
X1
Barcode scanner topside
X2
Barcode scanner underside
X3
X4
X5 Connection to the conveyor control
Connection
(current + control)
Switch
Barcode scanner
2
2
2
2
2
2 PCB barcode scanner assembly instructions SIPLACE
2.7 Installing the PCB barcode scanner 10/2009 Edition
174
: Set the relevant switch for the connected scanner to OFF and the others to ON.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2