00193891-0702_AI_LP_Barcode_DE+EN.pdf - 第181页
SIPLACE 2 PCB barcode scanner assembly instructions 10/2009 Edition 2.7 Installing the PCB barcode scanner 181 : Remove the to p of the extension kit (3 screws). 3 screws 2 : Mark the position of the slot. Location of th…

2 PCB barcode scanner assembly instructions SIPLACE
2.7 Installing the PCB barcode scanner 10/2009 Edition
180
2.7.5 Provide cable penetration (not SIPLACE S-27 HM)
: Remove the grille on the right side of the machine (2 screws).
2
2
: Check that provision is made for cable penetration.
Cable penetration
2
: If no cable penetration slot is provided, do the work described in this section.
If it is provided, proceed to
Chapter 2.7.6 .
Tools required 2
– Power drill or cordless screwdriver
– Drill bit (10 mm)
– Sliding gauge
– Compass saw or hacksaw.

SIPLACE 2 PCB barcode scanner assembly instructions
10/2009 Edition 2.7 Installing the PCB barcode scanner
181
: Remove the top of the extension kit (3 screws).
3 screws
2
: Mark the position of the slot.
Location of the new
cable penetration slot
22
22
22
160
Position of the drilled hole
2
2
2
Make sure that electrical components are protected from swarf while drilling and sawing. 2
2

2 PCB barcode scanner assembly instructions SIPLACE
2.7 Installing the PCB barcode scanner 10/2009 Edition
182
: Using the drill or cordless screwdriver, drill a 10 mm diameter hole (see diagram above for po-
sition).
: Cut out the slot with a compass saw or hacksaw.
: Deburr sharp edges.
: Refit the top of the extension kit.
2
2.7.6 Mechanical and electrical installation
: Unscrew the cover switch.
The screws are secured with locking adhesive.
2
2
: Remove the spacer block from the cover switch.
2
2
2