9.4.2 Functional Sequence "Forced Air" during Placement of a Com-
ponent
The sz axis sinks. Once the sz axis has reached its bottom position, with the end signal the forced air valve is
opened for about 30 - 40 msec and the component set down on the PCB. Following this period of time the sz
axis begins moving back upwards. While it is so moving, screwdriver 1 is activated in order to close the seg-
ment vacuum duct with the sealing piston. With the end signal from screwdriver 1 the forced air valve is closed
again. As as the "sz axis in top end position" bero has responded the revolver head can cycle on.
9.4.3 Functional Sequence "Forced Air" during Ejection of a Compo-
nent
The forced air valve for the ejection circuit opens for about 60 msec in order to eject the component. The valve
then closes. The vacuum test is used to check whether the component has been ejected - in other words, the
vacuum value is measured while the segment is open. Following this test, screwdriver 2 closes the nozzle by
moving the sealing piston forwards into the segment. Once the bero of screwdriver 2 has finally given the end
signal the revolver head can cycle on.
9 Revolver Head SIPLACE 80S/F/G Service Manual
Edition 04/97
9 - 20