ntcat.pdf - 第117页

18 18 10 0 % 10 0 % 10 0 % 10 0 % MONTHS W ARRANTY OF PRODUCTION TESTED DIMENSIONS TECHNICAL DATA Dimensions shown are metric (mm) 148 Consult “Precautions” page 327 before use, installation or service of MAC Valves.. Se…

100%1 / 280
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
147
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
Series
92
Function Port size Flow (Max) Individual mounting Series
5/2, 5/3
1/8” - 1/4” - 3/8”
1.2 C
v
Sub-base
non “plug-in”
1. The 4-way pilot develops maximum shifting
forces both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of
pressure, also provides high flow.
4. Short stroke with high flow.
5. Bonded seal spool with minimum friction,
shifting in a glass-like finished bore.
6. Pilot with balanced poppet, high flow; short
and consistent response times.
DM-D
XXX
-
XXX
*
SOLENOID OPERATOR
®
Voltage
JA
110 /50, 120/60 (2.9W)
JB
220/50, 240/60 (2.9W)
JC
24/60 (2.9W)
FB
24 VDC (1.8W)
DA
24 VDC (5.4W)
DF
24 VDC (12.7W)
Wire length
A
18” (Flying leads)
B
24” (Flying leads)
J
Connector
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
BM
Flying leads
BN
Flying leads with diode
BP
Flying leads with M.O.V.
BG
Flying leads with ground
JB
Rectangular connector
JD
Rectangular connector with light
KA
Square connector
XX X X XX
* Other options available, see page 309.
Other options available for the 92 series valves, see page 155.
5/2
Single operator
92B-ABA-000-DM-D
XXX
-
XXX
92B-ABA-AAG-DM-D
XXX
-
XXX
92B-ABA-BAG-DM-D
XXX
-
XXX
92B-ABA-CAG-DM-D
XXX
-
XXX
92B-ABA-AAH-DM-D
XXX
-
XXX
92B-ABA-BAH-DM-D
XXX
-
XXX
92B-ABA-CAH-DM-D
XXX
-
XXX
5/2
Double operator
92B-BBA-000-DM-D
XXX
-
XXX
92B-BBA-AAG-DM-D
XXX
-
XXX
92B-BBA-BAG-DM-D
XXX
-
XXX
92B-BBA-CAG-DM-D
XXX
-
XXX
92B-BBA-AAH-DM-D
XXX
-
XXX
92B-BBA-BAH-DM-D
XXX
-
XXX
92B-BBA-CAH-DM-D
XXX
-
XXX
5/3
Closed center
92B-EBA-000-DM-D
XXX
-
XXX
92B-EBA-AAG-DM-D
XXX
-
XXX
92B-EBA-BAG-DM-D
XXX
-
XXX
92B-EBA-CAG-DM-D
XXX
-
XXX
92B-EBA-AAH-DM-D
XXX
-
XXX
92B-EBA-BAH-DM-D
XXX
-
XXX
92B-EBA-CAH-DM-D
XXX
-
XXX
5/3
Open center
92B-FBA-000-DM-D
XXX
-
XXX
92B-FBA-AAG-DM-D
XXX
-
XXX
92B-FBA-BAG-DM-D
XXX
-
XXX
92B-FBA-CAG-DM-D
XXX
-
XXX
92B-FBA-AAH-DM-D
XXX
-
XXX
92B-FBA-BAH-DM-D
XXX
-
XXX
92B-FBA-CAH-DM-D
XXX
-
XXX
5/3
Pressure center
92B-GBA-000-DM-D
XXX
-
XXX
92B-GBA-AAG-DM-D
XXX
-
XXX
92B-GBA-BAG-DM-D
XXX
-
XXX
92B-GBA-CAG-DM-D
XXX
-
XXX
92B-GBA-AAH-DM-D
XXX
-
XXX
92B-GBA-BAH-DM-D
XXX
-
XXX
92B-GBA-CAH-DM-D
XXX
-
XXX
Port size
Valve less base
1/8” NPTF
1/4” NPTF
3/8” NPTF
1/8” NPTF
1/4” NPTF
3/8” NPTF
Pilot air
Internal
External
SINGLE PRESSURE MODELS
5/2
Single operator
92B-CBA-000-DM-D
XXX
-
XXX
92B-CBA-AAG-DM-D
XXX
-
XXX
92B-CBA-BAG-DM-D
XXX
-
XXX
92B-CBA-CAG-DM-D
XXX
-
XXX
92B-CBA-AAH-DM-D
XXX
-
XXX
92B-CBA-BAH-DM-D
XXX
-
XXX
92B-CBA-CAH-DM-D
XXX
-
XXX
5/2
Double operator
92B-DBA-000-DM-D
XXX
-
XXX
92B-DBA-AAG-DM-D
XXX
-
XXX
92B-DBA-BAG-DM-D
XXX
-
XXX
92B-DBA-CAG-DM-D
XXX
-
XXX
92B-DBA-AAH-DM-D
XXX
-
XXX
92B-DBA-BAH-DM-D
XXX
-
XXX
92B-DBA-CAH-DM-D
XXX
-
XXX
Port size
Valve less base
1/8” NPTF
1/4” NPTF
3/8” NPTF
1/8” NPTF
1/4” NPTF
3/8” NPTF
Pilot air
Internal
External
DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR – SEE "REGULATORS" SECTION)
Above models are shown with side ports.
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
148
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
92
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Internal pilot : 20 to 120 PSI 3 position : 35 to 120 PSI
External pilot : vacuum to 120 PSI 3 position : 35 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8": (1.0 C
v
) – 1/4": (1.1 C
v
) – 3/8": (1.2 C
v
)
Class A continuous duty, #22 AWG x 18 lead wire
-15% to +10% of nominal voltage
Consult factory
~Inrush 7.6 VA Holding : 4.8 VA
= 1.8 to 12.7 W
24V=/5.4W Energize : 8 ms De-energize : 7 ms
120/60 Energize : 7-13 ms De-energize : 12-20 ms
• BSPP threads • Sandwich flow control: FC92B-CA
• Pilot valve DM-Dxxx-xxx • Valve blanking plate: M-92002
• Pressure seal between valve and base : 16543. • Mounting screws valve to base (X2) : 35050.
Options :
Spare parts :
97,5
23.0
TYP.
6.0
20.0
40.0
9.0
21.0
55.6
33.3
15.0
4.0
16.0
32.0
76.0
9.5
31.0
4.0
43.8
24.5
84.5
F
E
G
14.5
145.3
115.8
B
A
C
D
1/8" external
pilot port
Double operator
Single operator
1/2" NPSM
conduit connection
4.25 dia.
Mtg Holes
DIM.
1/8"
1/4"
3/8"
A
12.5
12.5
12.0
B
18.0
18.0
17.0
C
31.0
31.0
30.0
D
54.0
54.0
54.0
E
23.5
23.5
23.5
F
46.5
46.5
47.5
G
18.0
18.0
17.0
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
149
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
Series
92
Function Port size Flow (Max) Individual mounting Series
5/2, 5/3
1/8” - 1/4” - 3/8”
1.2 C
v
Sub-base
“plug-in”
1. The 4-way pilot develops maximum shifting
forces both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of
pressure, also provides high flow.
4. Short stroke with high flow.
5. Bonded seal spool with minimum friction,
shifting in a glass-like finished bore.
6. Pilot with balanced poppet, high flow; short
and consistent response times.
* Other options available, see page 309.
Note: Ground required for 30 Volts or higher.
Other options available for the 92 series valves, see page 156.
5/2
Single operator
92B-AAA-000-DM-D
XX
P-
XXX
92B-AAA-AAA-DM-D
XX
P-
XXX
92B-AAA-BAA-DM-D
XX
P-
XXX
92B-AAA-CAA-DM-D
XX
P-
XXX
92B-AAA-AAD-DM-D
XX
P-
XXX
92B-AAA-BAD-DM-D
XX
P-
XXX
92B-AAA-CAD-DM-D
XX
P-
XXX
5/2
Double operator
92B-BAA-000-DM-D
XX
P-
XXX
92B-BAA-AAA-DM-D
XX
P-
XXX
92B-BAA-BAA-DM-D
XX
P-
XXX
92B-BAA-CAA-DM-D
XX
P-
XXX
92B-BAA-AAD-DM-D
XX
P-
XXX
92B-BAA-BAD-DM-D
XX
P-
XXX
92B-BAA-CAD-DM-D
XX
P-
XXX
5/3
Closed center
92B-EAA-000-DM-D
XX
P-
XXX
92B-EAA-AAA-DM-D
XX
P-
XXX
92B-EAA-BAA-DM-D
XX
P-
XXX
92B-EAA-CAA-DM-D
XX
P-
XXX
92B-EAA-AAD-DM-D
XX
P-
XXX
92B-EAA-BAD-DM-D
XX
P-
XXX
92B-EAA-CAD-DM-D
XX
P-
XXX
5/3
Open center
92B-FAA-000-DM-D
XX
P-
XXX
92B-FAA-AAA-DM-D
XX
P-
XXX
92B-FAA-BAA-DM-D
XX
P-
XXX
92B-FAA-CAA-DM-D
XX
P-
XXX
92B-FAA-AAD-DM-D
XX
P-
XXX
92B-FAA-BAD-DM-D
XX
P-
XXX
92B-FAA-CAD-DM-D
XX
P-
XXX
5/3
Pressure center
92B-GAA-000-DM-D
XX
P-
XXX
92B-GAA-AAA-DM-D
XX
P-
XXX
92B-GAA-BAA-DM-D
XX
P-
XXX
92B-GAA-CAA-DM-D
XX
P-
XXX
92B-GAA-AAD-DM-D
XX
P-
XXX
92B-GAA-BAD-DM-D
XX
P-
XXX
92B-GAA-CAD-DM-D
XX
P-
XXX
Port size
Valve less base
1/8”
1/4”
3/8”
1/8”
1/4”
3/8”
Pilot air
Internal
External
SINGLE PRESSURE MODELS
5/2
Single operator
92B-CAA-000-DM-D
XX
P-
XXX
92B-CAA-AAA-DM-D
XX
P-
XXX
92B-CAA-BAA-DM-D
XX
P-
XXX
92B-CAA-CAA-DM-D
XX
P-
XXX
92B-CAA-AAD-DM-D
XX
P-
XXX
92B-CAA-BAD-DM-D
XX
P-
XXX
92B-CAA-CAD-DM-D
XX
P-
XXX
5/2
Double operator
92B-DAA-000-DM-D
XX
P-
XXX
92B-DAA-AAA-DM-D
XX
P-
XXX
92B-DAA-BAA-DM-D
XX
P-
XXX
92B-DAA-CAA-DM-D
XX
P-
XXX
92B-DAA-AAD-DM-D
XX
P-
XXX
92B-DAA-BAD-DM-D
XX
P-
XXX
92B-DAA-CAD-DM-D
XX
P-
XXX
Port size
Valve less base
1/8”
1/4”
3/8”
1/8”
1/4”
3/8”
Pilot air
Internal
External
DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR – SEE "REGULATORS" SECTION)
Above models are shown with side ports.
Voltage
JA
110 /50, 120/60 (2.9W)
JB
220/50, 240/60 (2.9W)
JC
24/60 (2.9W)
FB
24 VDC (1.8W)
DA
24 VDC (5.4W)
DF
24 VDC (12.7W)
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
DM
Plug-in
DN
Plug-in with diode
DP
Plug-in with M.O.V.
DG
Plug-in with ground
DJ
Plug-in with M.O.V. & ground
DH
Plug-in with diode & ground
DM-D
XX
P-
XXX
*
SOLENOID OPERATOR
®
XX X XX