ntcat.pdf - 第23页
Function Port size Flow (Max) Individual mounting Series OPERATIONAL BENEFITS Direct solenoid and solenoid pilot operated valves HOW TO ORDER 27 Consult “Precautions” page 327 before use, installation or service of MAC V…

1/4" COMMONS
TYP. TYP.
86.0
15.0
16.5
15.0
8.3
5.0
22.2
59.2
51.3
14.1
9.0
35.2
9.3
4.7
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
26
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
36
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Protection :
Power :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1.8 Watt: (0.15 C
v
), 2.4 Watt: (0.15 C
v
), 5.4 Watt: (0.30 C
v
)
Class A wire (#22 AWG x 12), continuous duty
-15% to +10% of nominal voltage
Consult factory
5.4 W – 2.4 W – 1.8 W
• BSPP threads
• Inlet & exhaust isolator plate : N-36001 • Inlet isolator : N-36002
• Exhaust isolator : N-36003 • Tie rod (x2) : 79411
Option :
Spare parts :
Note: Isolator adds 2.5 mm
to length of stack.

Function Port size Flow (Max) Individual mounting Series
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
27
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
Series
36
3/2 1/8" - 5/32 Pressed-in 0.3 C
v
tube receptacle
Manifold base
“plug-in”
1. Balanced poppet, immune to variations of
pressure.
2. Patented solenoid develops high shifting
forces.
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
Port size
Valve less base
1/8” NPTF
5/32 tube receptacle
Universal Valve
Normally Closed
36A-J00-00-J
XX
P
-XXX
36A-JSA-AE-J
XX
P
-XXX
36A-JSF-AE-J
XX
P
-XXX
Universal Valve
Normally Open
36A-K00-00-J
XX
P
-XXX
36A-KSA-AF-J
XX
P
-XXX
36A-KSF-AF-J
XX
P
-XXX
Normally Closed Only
36A-L00-00-J
XX
P
-XXX
36A-LSA-AE-J
XX
P
-XXX
36A-LSF-AE-J
XX
P
-XXX
2
13
2
13
2
13
Voltage
AA
120 VAC (5.4W)
DA
24 VDC (5.4W)
DB
12 VDC (5.4W)
DC
24 VDC (2.4W)
DD
12 VDC (2.4W)
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
FA
Base plug-in
FB
Base plug-in with diode
FG
Base plug-in with rectifier
J
XX
P-
XXX
*
(-G) Add “G” for ground
SOLENOID OPERATOR
®
XX X XX
* Other options available, see page 317.
Note : AC voltage requires connector with rectifier.
Example : Manifold base only : 36A-0SA-AE (Normally closed manifold base).
End plate kit required (port size 1/4") : M-46003-01.

18.6
16.5
8.0
8.0
24.0
78.0
4.4
94.3
4.0
52.5
19.0
34.2
79.0
95.5
9.5
22.5
32.8
Ø 4.3
TYP. TYP.
TYP.
3/4"-14 NPSM
1/4" COMMONS
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
28
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
36
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Protection :
Power :
Compressed air, vacuum, inert gases
Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1.8W : (0.20 C
v
) – 2.4W : (0.20 C
v
) – 5.4W : (0.30 C
v
)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
Consult Factory
5.4 W – 2.4 W – 1.8 W
• BSPP threads
• Inlet isolator : 28501 • Exhaust isolator : 28502 • Valve cover plate : M-46002
• Tie rod (x2) : 79443
Option :
Spare parts :
Note: For Normally closed manifold the “A” port is plugged.