ntcat.pdf - 第81页
OPERATIONAL BENEFITS Direct solenoid and solenoid pilot operated valves HOW TO ORDER 101 Consult “Precautions” page 327 before use, installation or service of MAC Valves.. 36 32 37 38 33 34 52 67 46 44 47 42 400 48 92 93…

18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
100
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
3
1
5
12
2
4
12
2
4
3
1
5
12
4
2
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
2
4
2
4 4
2
18.5
10.5
5.5
22.4
23.8
12.8
FLOW CONTROL
SANDWICH
WITH OPTIONAL
95.1
76.5
TYP.
TYP.
TYP.
4.3
53.6
4.8
99.1
TYP.
TYP.
9.5
11.1
16.9
20.4
23.2
40.3
56.7
70.4
18.5 10.5
33.1
45.0
TYP.
TYP.
TYP.
TYP.
Ø 5.3
TYP.
6MM TUBE RECEPTACLES
M7, AND SCREW IN 1/4" AND
ARE AVAILABLE IN 10-32, M5,
*SIDE AND BOTTOM PORTS
6MM TUBE RECEPTACLES
FOR INTALLATION OF 1/4" AND
4MM HEX WRECH REQUIRED
IN TUBE RECEPTACLE
OPTIONAL SCREW
17.0
17.0
58.0
COMMONS
1/4" IN & EXH
PILOT COMMON
1/8" EXT.
(SHOWN WITH M7 PORTS)
120.3
Series
42
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 24V 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot - 2 pos. : 20 to 120 PSI 3 pos. : 40 to 120 PSI
External Pilot : vacuum to 120 PSI
2 position : 20 to 120 PSI 3 position : 40 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
# 10-32 : (0.35 C
v
) – 1/4” O.D. tube receptacle : (0.4 C
v
)
Class A wire (#22 AWG x 18), continuous duty
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 5 ms
De-energize : 5 ms
• M5 ports, M7 ports, 6 mm O.D. tube receptacles • Sandwich flow controls : FC42B-BB
• Sandwich regulator : see "regulators" section • Isolator disk for inlet or exhaust: 28454
• Valve blanking plate : M-42004
Options :

OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
101
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
5/2 Single solenoid
42B-AMA-000-G
XX
P-
XXX
42B-AMD-000-G
XX
P-
XXX
42B-AMA-AJA-G
XX
P-
XXX
42B-AMD-AJB-G
XX
P-
XXX
42B-AMA-EJA-G
XX
P-
XXX
42B-AMD-EJB-G
XX
P-
XXX
5/2 Double solenoid
42B-BME-000-G
XX
P-
X
ST
42B-BMH-000-G
XX
P-
X
ST
42B-BME-AJC-G
XX
P-
X
ST
42B-BMH-AJD-G
XX
P-
X
ST
42B-BME-EJC-G
XX
P-
X
ST
42B-BMH-EJD-G
XX
P-
X
ST
5/3 Closed center
42B-EME-000-G
XX
P-
X
ST
42B-EMH-000-G
XX
P-
X
ST
42B-EME-AJC-G
XX
P-
X
ST
42B-EMH-AJD-G
XX
P-
X
ST
42B-EME-EJC-G
XX
P-
X
ST
42B-EMH-EJD-G
XX
P-
X
ST
5/3 Open center
42B-FME-000-G
XX
P-
X
ST
42B-FMH-000-G
XX
P-
X
ST
42B-FME-AJC-G
XX
P-
X
ST
42B-FMH-AJD-G
XX
P-
X
ST
42B-FME-EJC-G
XX
P-
X
ST
42B-FMH-EJD-G
XX
P-
X
ST
24
12 14
315
24
12 14
315
24
12
14
315
24
12
14
315
Port size
Valve less
base
# 10-32
1/4” O.D.
tube receptacles
Pilot air
Internal
External
Internal
External
Internal
External
Series
42
Function Port size Flow (Max) Manifold mounting Series
5/2, 5/3 # 10-32 - 0.4 C
v
1/4”
O.D. tube receptacle
Manifold base
“plug-in”
1. 4-way valve with 4-way integral pilot.
2. 10 mm valve (stacks on 10.5 mm centers).
3. High flow (up to 0.4 C
v
).
4. Fast repeatable response times.
5. Maximum shifting forces in both directions.
6. Long life.
SINGLE PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS)
5/2 Single solenoid
42B-CMB-000-G
XX
P-
XXX
42B-CMC-000-G
XX
P-
XXX
42B-CMD-000-G
XX
P-
XXX
42B-CMB-AJA-G
XX
P-
XXX
42B-CMC-AJA-G
XX
P-
XXX
42B-CMD-AJB-G
XX
P-
XXX
42B-CMB-EJA-G
XX
P-
XXX
42B-CMC-EJA-G
XX
P-
XXX
42B-CMD-EJB-G
XX
P-
XXX
5/2 Double solenoid
42B-DMF-000-G
XX
P-
X
ST
42B-DMG-000-G
XX
P-
X
ST
42B-DMH-000-G
XX
P-
X
ST
42B-DMF-AJC-G
XX
P-
X
ST
42B-DMG-AJC-G
XX
P-
X
ST
42B-DMH-AJD-G
XX
P-
X
ST
42B-DMF-EJC-G
XX
P-
X
ST
42B-DMG-EJC-G
XX
P-
X
ST
42B-DMH-EJD-G
XX
P-
X
ST
5/3 Pressure center
42B-HMF-000-G
XX
P-
X
ST
42B-HMG-000-G
XX
P-
X
ST
42B-HMH-000-G
XX
P-
X
ST
42B-HMF-AJC-G
XX
P-
X
ST
42B-HMG-AJC-G
XX
P-
X
ST
42B-HMH-AJD-G
XX
P-
X
ST
42B-HMF-EJC-G
XX
P-
X
ST
42B-HMG-EJC-G
XX
P-
X
ST
42B-HMH-EJD-G
XX
P-
X
ST
Port size
Valve less base
# 10-32
1/4” O.D.
tube receptacles
Pilot air
Internal Supply #3 port
Supply #5 port
External
Internal Supply #3 port
Supply #5 port
External
Internal Supply #3 port
Supply #5 port
External
DUAL PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS)
Voltage
AA
120 VAC (2.5W)
DC
24 VDC (1.8W)
DD
24 VDC (2.5W)
DF
24 VDC (4.0W)
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
Double solenoid & 3 position models
ST
Base plug-in
Single solenoid models
SA
Base plug-in
SJ
Base plug-in with light
SS
Base plug-in with rectifier & light & ground
G
XX
P-
XXX
*
STANDARD SOLENOID OPERATOR
®
XX X XX
* Other options available, see page 311.
** Latching solenoid available for 5/2 valves.
Note : - AC voltage requires connector with rectifier (for double solenoid consult factory).
- Manifold assemblies consist of (1) left end manifold, (1) right end
manifold, and middle station manifolds (options "J" or "K").
Other options available for the 42 series valves, see page 108.
Above numbers are middle station manifolds with side ports
24
12
14
315
24
1214
3
1
5
24
1214
3
1
5

12
MODIF.
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODEL
12
MODEL
12
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
12
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
4
2
4
2
X
5
3
1
X
5
3
1
2
4
4
2
18.5 10.5
33.1
45.0
TYP.
TYP.
TYP.
TYP.
6MM TUBE RECEPTACLES
FOR INTALLATION OF 1/4" AND
4MM HEX WRECH REQUIRED
4
2
4
2
MODIF.
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
4
2
2
4
68.4
17.0
17.0
IN TUBE RECEPTACLE
OPTIONAL SCREW
5
1
10.5
23.7
66.5
5.5
16.9
4.3
5.0
TYP.
TYP.
11.1
9.5
16.9
22.0
20.0
23.2
40.4
56.7
68.5
94.0
114.0
TYP.
Ø 5.3
TYP.
12.8
18.5
COMMONS
1/4" IN & EXH
CONDUIT
1"-11 1/2
75.0
23.2
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
102
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
42
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 24V 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot - 2 pos. : 20 to 120 PSI 3 pos. : 40 to 120 PSI
External Pilot : vacuum to 120 PSI
2 position : 20 to 120 PSI 3 position : 40 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
# 10-32 : (0.35 C
v
) – 1/4” O.D. tube receptacle : (0.4 C
v
)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 5 ms
De-energize : 5 ms
• M5 ports, M7 ports, 6 mm O.D. tube receptacles • Sandwich flow controls : FC42B-AB
• Sandwich regulator : see "regulators" section • Isolator disk for inlet or exhaust: 28454
• Valve blanking plate : M-42004 • Plug-in wire protector : 24180
Options :