ntcat.pdf - 第131页

5.85 57.0 28.5 13.0 31.65 36.0 A B E F 80.0 53.0 1/8" -27 NPTF EXTERNAL PILOT PORT 111.6 H G D C 1/2" -14 N.P .S.M. CONDUIT PORT 185.4 156.9 DOUBLE SOLENOID SINGLE SOLENOID 20.0 6.00 39.1 71.7 96.0 5.3 DIA 2 MT…

100%1 / 280
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
161
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
Series
93
Function Port size Flow (Max) Individual mounting Series
5/2, 5/3
1/4” - 3/8” - 1/2”
3.4 C
v
Sub-base
non “plug-in”
1. Unique patented Macsolenoid® for fastest
possible response times and virtually
burn-out proof solenoid operation.
2. Balanced poppet 4-way pilot valve provides
maximum shifting forces, precise
repeatability and consistent operation.
3. Air only return. Optional memory spring is
also available.
4. Optional low wattage DC solenoid down to
1 watt.
5. MAC spool and bore combination wipes
away contamination, eliminates sticking and
allows for use on non-lube service.
DM-D
XXX
-
XXX
*
SOLENOID OPERATOR
®
Voltage
JA
110/50, 120/60
JB
220/50, 240/60
JC
24/50, 24/60
FB
24 VDC (1.8W)
DA
24 VDC (5.4W)
DF
24 VDC (12.7W)
Wire length
A
18” (Flying leads)
B
24” (Flying leads)
J
Connector
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
BM
Flying leads
BN
Flying leads with diode
BP
Flying leads with M.O.V.
BG
Flying leads with ground
JB
Rectangular connector
JD
Rectangular connector with light
XX X X XX
* Other options available, see page 309.
Other options available for the 93 series valves, see page 169.
5/2
Single operator
93A-ABA-000-DM-D
XXX
-
XXX
93A-ABA-ABG-DM-D
XXX
-
XXX
93A-ABA-BAG-DM-D
XXX
-
XXX
93A-ABA-CAG-DM-D
XXX
-
XXX
93A-ABA-ABH-DM-D
XXX
-
XXX
93A-ABA-BAH-DM-D
XXX
-
XXX
93A-ABA-CAH-DM-D
XXX
-
XXX
5/2
Double operator
93A-BBA-000-DM-D
XXX
-
XXX
93A-BBA-ABG-DM-D
XXX
-
XXX
93A-BBA-BAG-DM-D
XXX
-
XXX
93A-BBA-CAG-DM-D
XXX
-
XXX
93A-BBA-ABH-DM-D
XXX
-
XXX
93A-BBA-BAH-DM-D
XXX
-
XXX
93A-BBA-CAH-DM-D
XXX
-
XXX
5/3
Closed center
93A-EBA-000-DM-D
XXX
-
XXX
93A-EBA-ABG-DM-D
XXX
-
XXX
93A-EBA-BAG-DM-D
XXX
-
XXX
93A-EBA-CAG-DM-D
XXX
-
XXX
93A-EBA-ABH-DM-D
XXX
-
XXX
93A-EBA-BAH-DM-D
XXX
-
XXX
93A-EBA-CAH-DM-D
XXX
-
XXX
5/3
Open center
93A-FBA-000-DM-D
XXX
-
XXX
93A-FBA-ABG-DM-D
XXX
-
XXX
93A-FBA-BAG-DM-D
XXX
-
XXX
93A-FBA-CAG-DM-D
XXX
-
XXX
93A-FBA-ABH-DM-D
XXX
-
XXX
93A-FBA-BAH-DM-D
XXX
-
XXX
93A-FBA-CAH-DM-D
XXX
-
XXX
Port size
Valve less base
1/4” NPTF
3/8” NPTF
1/2” NPTF
1/4” NPTF
3/8” NPTF
1/2” NPTF
Pilot air
Internal
External
SINGLE PRESSURE MODELS (1/4" MODELS ARE BOTTOM PORTED)
5/2
Single operator
93A-CBA-000-DM-D
XXX
-
XXX
93A-CBA-ABG-DM-D
XXX
-
XXX
93A-CBA-BAG-DM-D
XXX
-
XXX
93A-CBA-CAG-DM-D
XXX
-
XXX
93A-CBA-ABH-DM-D
XXX
-
XXX
93A-CBA-BAH-DM-D
XXX
-
XXX
93A-CBA-CAH-DM-D
XXX
-
XXX
5/2
Double operator
93A-DBA-000-DM-D
XXX
-
XXX
93A-DBA-ABG-DM-D
XXX
-
XXX
93A-DBA-BAG-DM-D
XXX
-
XXX
93A-DBA-CAG-DM-D
XXX
-
XXX
93A-DBA-ABH-DM-D
XXX
-
XXX
93A-DBA-BAH-DM-D
XXX
-
XXX
93A-DBA-CAH-DM-D
XXX
-
XXX
5/3
Pressure center
93A-HBA-000-DM-D
XXX
-
XXX
93A-HBA-ABG-DM-D
XXX
-
XXX
93A-HBA-BAG-DM-D
XXX
-
XXX
93A-HBA-CAG-DM-D
XXX
-
XXX
93A-HBA-ABH-DM-D
XXX
-
XXX
93A-HBA-BAH-DM-D
XXX
-
XXX
93A-HBA-CAH-DM-D
XXX
-
XXX
Port size
Valve less base
1/4” NPTF
3/8” NPTF
1/2” NPTF
1/4” NPTF
3/8” NPTF
1/2” NPTF
Pilot air
Internal
External
DUAL PRESSURE MODELS
REQUIRE SANDWICH REGULATOR, SEE „REGULATORS“ SECTION (1/4" MODELS ARE BOTTOM PORTED)
BA
B
A
EB IN EA
5.85
57.0
28.5
13.0
31.65
36.0
A
B
E
F
80.0
53.0
1/8" -27 NPTF
EXTERNAL
PILOT PORT
111.6
H
G
D
C
1/2" -14 N.P.S.M.
CONDUIT PORT
185.4
156.9
DOUBLE SOLENOID
SINGLE SOLENOID
20.0
6.00
39.1
71.7
96.0
5.3 DIA
2 MTG. HOLES
23.00
46.00
OPTIONAL BOTTOM PORTS
3/8" AND 1/4" ONLY
ML
K
J
EP
IN
EX
CONDUIT
CYL. B
CYL. A
IN
EX
A
B
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
162
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
93
Fluid :
Pressure range :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Protection :
Power :
Response times :
(with 5.4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot: 20 to 120 PSI
External Pilot: Vacuum to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/4”, 3/8” : (3.0 C
v
) - 1/2” : (3.4 C
v
)
Class A continuous duty, #22 AWG x 18 leads
-15% to +10% of nominal voltage
Consult factory
~ Inrush 7.6 VA Holding: 4.8 VA
= 1 to 12.7 W
Energize : 13 ms
De-energize : 10 ms
• BSPP thread • Sandwich regulator (see ‚regulators‘ section)
• Sandwich flow controls FC93A-BA (screwdriver slot adjustment)
FC93A-BB (locking knob adjustment)
• Pilot valve: DM-Dxxx-xxx • Valve to base pressure seal: 16622
• Pilot valve pressure seal: 16542 • Mounting screws valve to base (x4): 35249
• Pilot valve mounting screws (x2): 35069
Options :
Spare parts :
DIM.
3/8"
1/2"
A
27.15
25.5
B
20.65
19.0
C
27.15
25.5
D
24.15
22.5
E
54.1
45.8
F
81.7
75.3
G
38.2
38.2
H
73.5
73.5
DIM.
1/4"
3/8"
J
7.0
8.5
K
14.7
16.2
L
15.0
16.5
M
16.5
17.5
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
163
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
Series
93
Function Port size Flow (Max) Individual mounting Series
5/2, 5/3
1/4” - 3/8” - 1/2”
3.4 C
v
Sub-base
“plug-in”
1. Unique patented Macsolenoid® for fastest
possible response times and virtually
burn-out proof solenoid operation.
2. Balanced poppet 4-way pilot valve provides
maximum shifting forces, precise
repeatability and consistent operation.
3. Air only return. Optional memory spring is
also available.
4. Optional low wattage DC solenoid down to
1 watt.
5. MAC spool and bore combination wipes
away contamination, eliminates sticking and
allows for use on non-lube service.
* Other options available, see page 309.
Note: Ground required for 30 Volts or higher.
Other options available for the 93 series valves, see page 170.
5/2
Single operator
93A-AAA-000-DM-D
XX
P-
XXX
93A-AAA-ABA-DM-D
XX
P-
XXX
93A-AAA-BAA-DM-D
XX
P-
XXX
93A-AAA-CAA-DM-D
XX
P-
XXX
93A-AAA-ABD-DM-D
XX
P-
XXX
93A-AAA-BAD-DM-D
XX
P-
XXX
93A-AAA-CAD-DM-D
XX
P-
XXX
5/2
Double operator
93A-BAA-000-DM-D
XX
P-
XXX
93A-BAA-ABA-DM-D
XX
P-
XXX
93A-BAA-BAA-DM-D
XX
P-
XXX
93A-BAA-CAA-DM-D
XX
P-
XXX
93A-BAA-ABD-DM-D
XX
P-
XXX
93A-BAA-BAD-DM-D
XX
P-
XXX
93A-BAA-CAD-DM-D
XX
P-
XXX
5/3
Closed center
93A-EAA-000-DM-D
XX
P-
XXX
93A-EAA-ABA-DM-D
XX
P-
XXX
93A-EAA-BAA-DM-D
XX
P-
XXX
93A-EAA-CAA-DM-D
XX
P-
XXX
93A-EAA-ABD-DM-D
XX
P-
XXX
93A-EAA-BAD-DM-D
XX
P-
XXX
93A-EAA-CAD-DM-D
XX
P-
XXX
5/3
Open center
93A-FAA-000-DM-D
XX
P-
XXX
93A-FAA-ABA-DM-D
XX
P-
XXX
93A-FAA-BAA-DM-D
XX
P-
XXX
93A-FAA-CAA-DM-D
XX
P-
XXX
93A-FAA-ABD-DM-D
XX
P-
XXX
93A-FAA-BAD-DM-D
XX
P-
XXX
93A-FAA-CAD-DM-D
XX
P-
XXX
Port size
Valve less base
1/4” NPTF
3/8” NPTF
1/2” NPTF
1/4” NPTF
3/8” NPTF
1/2” NPTF
Pilot air
Internal
External
SINGLE PRESSURE MODELS (1/4" MODELS ARE BOTTOM PORTED)
5/2
Single operator
93A-CAA-000-DM-D
XX
P-
XXX
93A-CAA-ABA-DM-D
XX
P-
XXX
93A-CAA-BAA-DM-D
XX
P-
XXX
93A-CAA-CAA-DM-D
XX
P-
XXX
93A-CAA-ABD-DM-D
XX
P-
XXX
93A-CAA-BAD-DM-D
XX
P-
XXX
93A-CAA-CAD-DM-D
XX
P-
XXX
5/2
Double operator
93A-DAA-000-DM-D
XX
P-
XXX
93A-DAA-ABA-DM-D
XX
P-
XXX
93A-DAA-BAA-DM-D
XX
P-
XXX
93A-DAA-CAA-DM-D
XX
P-
XXX
93A-DAA-ABD-DM-D
XX
P-
XXX
93A-DAA-BAD-DM-D
XX
P-
XXX
93A-DAA-CAD-DM-D
XX
P-
XXX
5/3
Pressure Center
93A-HAA-000-DM-D
XX
P-
XXX
93A-HAA-ABA-DM-D
XX
P-
XXX
93A-HAA-BAA-DM-D
XX
P-
XXX
93A-HAA-CAA-DM-D
XX
P-
XXX
93A-HAA-ABD-DM-D
XX
P-
XXX
93A-HAA-BAD-DM-D
XX
P-
XXX
93A-HAA-CAD-DM-D
XX
P-
XXX
Port size
Valve less base
1/4” NPTF
3/8” NPTF
1/2” NPTF
1/4” NPTF
3/8” NPTF
1/2” NPTF
Pilot air
Internal
External
DUAL PRESSURE MODELS
REQUIRE SANDWICH REGULATOR, SEE „REGULATORS“ SECTION (1/4" MODELS ARE BOTTOM PORTED)
BA
B
A
EB IN EA
Above models are shown without light.
Voltage
JA
110/50, 120/60 (2.9W)
JB
220/50, 240/60 (2.9W)
JC
24/50, 24/60 (2.9W)
FB
24 VDC (1.8W)
DA
24 VDC (5.4W)
DF
24 VDC (12.7W)
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
DM
Plug-in
DN
Plug-in with diode
DP
Plug-in with M.O.V.
DG
Plug-in with ground
DM-D
XX
P-
XXX
*
SOLENOID OPERATOR
®
XX X XX