ntcat.pdf - 第46页

Function Port size Flow (Max) Manifold mounting Series OPERATIONAL BENEFITS Direct solenoid and solenoid pilot operated valves HOW TO ORDER 57 Consult “Precautions” page 327 before use, installation or service of MAC Val…

100%1 / 280
131.0
9.7
4.0
115.8
6.4
50.4
VAC TO 150 PSI
MODIF.
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODEL
23.3
8.0
2
76.0
31.5
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
56
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
38
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 C
v
) - 1/8" side port: (1.0 C
v
) - 1/4” tube receptacle: (0.85 C
v
)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :
Function Port size Flow (Max) Manifold mounting Series
OPERATIONAL BENEFITS
Direct solenoid and solenoid pilot operated valves
HOW TO ORDER
57
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
36
32
37
38
33
34
52
67
46
44
47
42
400
48
92
93
ISO 1
ISO 2
ISO 3
69
48P
ISO 01
ISO 02
Series
38
3/2 NO-NC 1/8” - 1.2 C
v
1/4”
O.D. tube receptacle
Manifold base
“plug-in”
1. 3-way valve with 4-way integral pilot.
2. 10 mm valve (stacks on 16.5 mm centers).
3. High flow (up to 1.2 C
v
).
4. Fast, repeatable response times.
5. Maximum shifting forces in both directions.
38B-
XXX
-
X
J
X
-G
XX
P-
XXX
OPTIONS
J Manifold base – Side port
K Manifold base – Bottom port
L Left end manifold base – Side port
M Left end manifold base – Bottom port
N Right end manifold base – Side port
P Right end manifold base – Bottom port
Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold and middle station manifolds (options "J" or "K").
NO valve
38B-BMA-000-G
XX
P-
XXX
38B-BMB-000-G
XX
P-
XXX
38B-BMA-AJA-G
XX
P-
XXX
38B-BMB-AJB-G
XX
P-
XXX
38B-BMA-EJA-G
XX
P-
XXX
38B-BMB-EJB-G
XX
P-
XXX
NC valve
38B-AMA-000-G
XX
P-
XXX
38B-AMB-000-G
XX
P-
XXX
38B-AMA-AJA-G
XX
P-
XXX
38B-AMB-AJB-G
XX
P-
XXX
38B-AMA-EJA-G
XX
P-
XXX
38B-AMB-EJB-G
XX
P-
XXX
Universal valve
38B-GMB-000-G
XX
P-
XXX
38B-GMB-BJB-G
XX
P-
XXX
38B-GMB-EJB-G
XX
P-
XXX
Port size
Valve less base
1/8” NPTF
1/4” O.D.
Tube receptacle
Pilot air
Internal
External
Internal
External
Internal
External
Note : Above codes are for side port.
Voltage
AA
120 VAC (2.5W)
DA
24 VDC (1.0W)
DC
24 VDC (1.8W)
DD
24 VDC (2.5W)
DF
24 VDC (4.0W)
Manual operator
1
Non-locking recessed
2
Locking recessed
Electrical connection
SA
Base plug-in
SJ
Base plug-in with light
SS
Base plug-in with rectifier & light & ground
G
XX
P-
XXX
*
STANDARD SOLENOID OPERATOR
®
XX X XX
Note : AC voltage requires connector with rectifier.
* Other options available, see page 311.
Latching solenoid also available, see page 61.
Washdown capability is possible, consult factory for modification number.
Base Configuration :
38B-000-
XXX
(i.e. 38B-000-AJA)
Base only :
2
1210
13
2
1210
13
2
1210
13
18
18
10 0
%
10 0
%
10 0
%
10 0
%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
DIMENSIONS
TECHNICAL DATA
Dimensions shown are metric (mm)
58
Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Series
38
CONDUIT
3/4"-14
51.5
16.5
23.3
2222
47.5
55.5
33.5
29.5
12.0
16.7
107.1
82.3
72.7
28.4
TYP.
TYP.
TYP.
4.0
9.7
TYP.
TYP.
TYP.
23.3
16.5
31.5
8.0
VAC TO 150 PSI
MODIF.
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODEL
2
Ø 5.3
TYP.
1/4" O.D. TUBE FITTING
1/8" TAPPED OR
3/8" IN & EXH
EXT. PILOT
1/8" COMMON
1/4" O.D. TUBE FITTING
1/8" TAPPED OR
131.0
115.8
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
VAC TO 150 PSI
VAC TO 150 PSI
MODIF.
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODEL
2
1
3
EP
COND
22
MODEL
AUCKLAND, N.Z.
LIEGE, BELGIUM
WIXOM, MI. USA
MODIF.
VAC TO 150 PSI
76.0
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Temperature range :
Flow :
Coil :
Voltage range :
Power :
Response times :
(with 4 W coil)
Compressed air, vacuum, inert gases
Internal Pilot : 20 to 120 PSI
External Pilot : Vacuum to 120 PSI
20 to 120 PSI
Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)
40 µ
0°F to 120°F (-18°C to +50°C)
1/8" bottom port: (1.2 C
v
) - 1/8" side port: (1.0 C
v
) - 1/4” tube receptacle: (0.85 C
v
)
Class A continuous duty, #22 AWG x 12 base leads
-15% to +10% of nominal voltage
1.0 to 4.0 W
Energize : 6 ms
De-energize : 6 ms
• BSPP threadsOptions :