1_H24维修手册.pdf - 第201页

E d i ti o n 5 . 0 H 24 H ead R ep ai r T r ai n i n g T ext f o r S er vi ce E n g i n e e r s I PS C a m e r a p o s i ti o n a d j u s tm e n t fo r H 2 4 h e a d u s i n g h e a d b e n c h 2 .6 Ad j u s t i ng t he …

100%1 / 214
Edition 5.0 H24 Head Repair Training Text for Service Engineers
IPS Camera position adjustment for H24 head using head bench
Inspection item
Tolerance
Target value
Camera resolution
L: X = 92~108
L: Z = 92~108
Same as tolerance
Center value
R: Xs = 380~400, Zp = 235~255
L: Xp = 80~100, Zp = 237~253
R: Xs = 390, Zp = 245
L: Xp = 90, Zp = 245
Tilt
R: dX = 0~6, dZ = 0~9
L: dX = 0~6, dZ = 0~9
R: dX = 0, dZ = 0
L: dX = 0, dZ = 0
1. If the results are within tolerance, press the lower button to save the settings.
2. Once saving the settings, remove the jig nozzles (2AGKNJ001500).
Resolution
Center value
Tilt
FK-9F50-08-0E S2-8 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
IPS Camera position adjustment for H24 head using head bench
2.6 Adjusting the Current Value (Grayscale Value)
1. Press the upper button to change to [ADJUSTMENT 2] mode. Press the lower button
to display the current and grayscale values.
2. Press the upper and lower buttons simultaneously to reverse the LCD contrast, and
then check there are no white areas within the green rectangles.
Grayscale
values
Current
values
FK-9F50-08-0E S2-9 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
IPS Camera position adjustment for H24 head using head bench
3. Block the right-hand glass and check there is no effect on the left-hand area. Block the
left-hand glass and check there is no effect on the right-hand area.
4. Press the upper and lower buttons simultaneously to set the LCD contrast back to
normal.
5. Rotate the R-axis through one full rotation and confirm that there is no position where
the variation in the grayscale values (GR and GL) is extreme. If the grayscale value is
too big, check the fluorescent status. If it is dirty, clean or replace it as necessary.
6. Rotate the R-axis by hand to find the positions where the grayscale values (GR and
GL) are maximized and minimized. Check that the minimum and maximum grayscale
values are within the tolerance of 120~160 (target: 120). Also check that the current
value is 24mA or less.
7. If the grayscale values are not within the target values, adjust them as shown below.
8. Press the lower button to display CURRENT UP or CURRENT DOWN. When
raising the value, display CURRENT UP and press the lower button to adjust the
value. When lowering the value, display CURRENT DOWN and press the lower
button to adjust the value.
FK-9F50-08-0E S2-10 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8