1_H24维修手册.pdf - 第72页

Edi t i on 5 .0 H 24 H e ad R e p ai r T r a i n i n g T ext f o r S er vi ce E n g i n eer s A dj us t i n g t h e N o z z l e L o w er i n g L ever C h eck S en so r a nd M ea su r i n g t h e A i r P r essu r e 6 . 2 …

100%1 / 214
Edition 5.0
H24 Head Repair Training Text for Service Engineers
Adjusting the Nozzle Lowering Lever Check Sensor and Measuring the Air Pressure
11. Click [Nozzle Lowering Lever].
12. The following message displays. Click [OK] and use a wrench to flip the lever to the
side and return it to its original position. Check that OK displays in the box under the
[Nozzle Lowering Lever] command.
13. Close the CheckTester software, turn the I/O check jig power OFF and then disconnect
the head communication cable from the I/O check jig.
FK-9F50-08-0E
6-5
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0
H24 Head Repair Training Text for Service Engineers
Adjusting the Nozzle Lowering Lever Check Sensor and Measuring the Air Pressure
6.2 Vacuum Break Pressure Measurement
Head Air Pressure Table
Caution: The values in the table apply to new heads and should only be
used as a reference for used heads.
1. Set 0.7 mm nozzles on all the syringes except the one you will measure (23 syringes),
and then attach the head to the I/O check jig (AA1RS0*).
2. Turn the head/nozzle changer I/O check jig power OFF. Connect the communication
cable to the head.
1. H24
Vacuum Break
Pressure: 4.0
5.0 kPa
Flow: 0.1 l/min or more
Nozzle cleaning
(Source pressure is -
91.8kpa.)
Pressure: 10 kPa or more
Flow: 2.0 l/min or more
Vacuum
(Source pressure is -
91.8kpa)
Pressure: -85
-91.8 kPa
FK-9F50-08-0E
6-6
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0
H24 Head Repair Training Text for Service Engineers
Adjusting the Nozzle Lowering Lever Check Sensor and Measuring the Air Pressure
3. Turn the head/nozzle changer I/O check jig (AA1SB0*) power ON.
4. Start the computer and open the IO_CheckTester_V370” software.
5. Click the button below to select the H24 head.
6. The following window appears. Select H24 from the dropdown list in [Head Type].
Click here
FK-9F50-08-0E
6-7
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998