Edition 5.0
H24 Head Repair Training Text for Service Engineers
Replacing the Z axis motor
Chapter 2 - Replacing the Z axis Motor
The Z-axis motor replacement procedure is explained below.
Note: Be sure to prepare a replacement motor with terminals attached.
Note: Z-axis proper data measurement is required following replacement of the Z-axis
motor.
2.1 Remove the Z axis
1. Remove the following cover from the head.
2. Remove the connectors from the control board.
FK-9F50-08-0E 2-1
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8