WinMCS_Manual(ENG) rev1.0.pdf - 第25页

25 Service Manual Koh Y oung T echnology Inc. 3. LANE TYPE Select the right o ne depending on how many l anes are i n machine to perform PCB inspection. If there are two lanes, it is Dua l lane . And if there is onl y on…

100%1 / 67
24
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
CONVEYOR
1. Fixed Part:
Set this option as Front Fixed or Rear Fixed at where the rail is fixed.
2. PCB Flow Direction
0. Left-> Right: PCB flows from left side to right side.
1. Right-> Left: PCB flows from right side to left side.
25
Service Manual
Koh Young Technology Inc.
3. LANE TYPE
Select the right one depending on how many lanes are in machine to perform PCB
inspection. If there are two lanes, it is Dual lane. And if there is only one lane, it is Single
lane.
4. Stage Type
There are two types of stage for Conveyor as 1 Stage or 3 Stage. Usually 3030VA or 3030VAL
machine is 3Stage type and 8030s is 1Stage type. (It may differ due to the customers
request.)
BOARD VERSION(STMC)
0. Below Ver 4.5: Applicable for below STMC Board 4.1
1. Above Ver 5.1: From STMC Board 5.1
2. Above Ver 5.1 HS: From STMC Board 5.1 with High Speed spec.
26
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
STMC CONVEYOR BELT SPEED ADJUSTMENT(Available from STMC Firmware
Ver. 520)
1. Above STMC F/W Version 520:
Belt speed option is activated when the check box is enabled.
2. Belt Max Speed:
Set the belt speed when the inspection starts.
3. Decel Distance:
Default value.
4. Belt Step Size:
Default value.
5. Sen To Stopper Dist:
Set the distance between work out sensor and work stopper. (Factory Setting)
GUI VER
1. GUI TYPE:
0. Old SPI: OLD GUI(Standard) version
1. New SPI: New GUI version
2. Default: Not applicable