53
Service Manual
Koh Young Technology Inc.
2. SetBack 1 Outlet Option :
0. DON’T USE: Do not use SetBack 1 Outlet Mode.
1. OUTLET_PASS: After inspecting PCB when it arrives at the work position from Entry,
the request signal would come from the previous machine. Then, pass it to the previous
machine.
PCB PCB
PCB PCB
[Figure 1. Inspection] [Figure 2. Pass the PCB after inspection]
2. ENTRY STOP: After inspecting PCB as below picture, PCB is stopped at the entry
position. The user has to remove the PCB at this moment and load it again at the entry
position. Then, repeat it.
PCB PCB
PCB
PCB
[Figure 1. Inspection] [Figure 2. Stop at the entry after inspection]
3. Belt LD Option: PCB Loading Option
Entry Sensor:
When Entry In Sensor detects a PCB, conveyor belt moves.
Entry & Smema:
When the Smema Ready signals of both Entry In and previous machine are on, conveyor
belt moves.
Max Warpage Limit Setting
It is to set the warpage limit. If the warpage larger than the set value occurs when Z-
Tracking Inspection, it is judged error.

54
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
4.7. MULTI FIDUCIAL INSPECTION
It is setting for Multi Fiducial.
Location: Menu Settings SystemSettings MULTIFID
4.7.1. MULTI FID
It is to set a function to inspect using Multi Fiducial.

55
Service Manual
Koh Young Technology Inc.
ScaleFactor Setting
1. Origin ScaleFactor (Zoom 1 Position)
Input the machine ScaleFactor values which are set in GUI.
2. Zoom 2 Scalefactor
If Step Zoom option is used, input Zoom2 Position Scalefactor values.
If Step Zoom option is not used, no need to input this column.
3. Zoom 3 Scalefactor
If Step Zoom option is used, input Zoom3 Position Scalefactor values.
If Step Zoom option is not used, no need to input this column.
2 Fiducial Auto Scale per Board
1. 2 FID MULTI INSP
0. Don’t Use: 2 Fiducial Auto Scale per Board is not used.
1. Default (Use): Using 2 fiducial marks to inspect scale.
2. 1 Fid (Use): Using 1 fiducial mark to inspect scale.