WinMCS_Manual(ENG) rev1.0.pdf - 第43页

43 Service Manual Koh Y oung T echnology Inc.  Def ect op tion Defect Option: 0. Default : Norm al Defect Sequence ( Default Optio n) 1. Change : On a uto operato r option, a PCB wi ll stay on machine unti l the inspect…

100%1 / 67
42
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
3. Stopper and Belt Delay:
If a PCB is sent out to the next machine right after the stopper is up, the solder pastes of the
PCB might get damaged by the stopper. To avoid this damage, it is recommended to take
some delay time and run the conveyor belt after Stopper is up
4. PCB_Unloading Delay:
When SMEMA signal is terminated, if the belt stops running right after the termination, the
target PCB might not move to the next machine in cases that the target PCB is heavy or the
level with next Mounter machine is not good. In these cases, having delay time on machine
might help the PCB move out on the conveyor smoothly.
PreBarcode option
Conv Option:
0. Single -> Single: Default Option
1. Single -> Dual: Option for Virtual DualLane (DualLane GUI, OneStage Conveyor)
43
Service Manual
Koh Young Technology Inc.
Defect option
Defect Option:
0. Default: Normal Defect Sequence (Default Option)
1. Change: On auto operator option, a PCB will stay on machine until the inspection result
is shown if a defect is found in the PCB. If you click NG button, it will stay on the state of
STOP and if you click RUN button, PCB will be sent to next machine.
Backup Option(Warpage Option)
1. Lane 1 Backup
0. Dont Use: Backup Pin Unit is not used.
1. USE: Backup Pin Unit is used
2. Lane 2 Backup
0. Dont Use: Backup Pin Unit is not used.
1. USE: Backup Pin Unit is used
3. Backup Pin Sol Time : Backup Pin Up/Down Time Delay
Input Backup Pin Sol Up/Down delay time (Default: 0ms)
44
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
Select Z Move(Warpage Option)
This is the option for adjusting Z axis focus during a PCB inspection.
Select Z Move:
0. Dont Use: No adjustment of the focus height of Z axis during inspection (Default)
1. USE: Adjust the focus height of Z axis as referred to the Job File during inspection.
Inside View Lamp
It is a lamp installed inside the machine for checking without opening the door. This lamp
is turned off during inspection and turned on when the machine is on standby.
N
N
o
o
t
t
e
e
This function(Inside View Lamp) is not applicable yet.