WinMCS_Manual(ENG) rev1.0.pdf - 第59页
59 Service Manual Koh Y oung T echnology Inc. 1. USER T OW ER LAMP SETUP This setting is f or the tower lamp on machine. It can be set separately by the machine mod e. [ Machine Mod e ] IDLE&RUN, RESET&EM G, ERRO…

58
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
5. TOWER LAMP SETTING
It is setting for Lamp On/Off and alarm for each machine mode.
5.1. TOWER LAMP SETTING

59
Service Manual
Koh Young Technology Inc.
1. USER TOWER LAMP SETUP
This setting is for the tower lamp on machine. It can be set separately by the machine mode.
[ Machine Mode ]
IDLE&RUN, RESET&EMG, ERROR&STOP, HOME&DEFECT, WAIT RUN
The tower lamp with red, yellow and green color indicates the machine status. And alarm
sound also can be used to let operator know the status.
0. OFF: Lamp is off.
1. ON: Lamp is on.
2. TOGGLE: Lamp is blinking
2. Toggle Time Setting
If lamp mode is set to TOGGLE, the lamp will blink for the set time.

60
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
6. MACHINE CALIBRATION (Kohyoung Level)
It describes how to use Machine Calibration Wizard.
6.1. MACHINE CALIBRATION WIZARD
N
N
o
o
t
t
e
e
For more information, please refer to X,Y Machine Calibration manual.