WinMCS_Manual(ENG) rev1.0.pdf - 第57页

57 Service Manual Koh Y oung T echnology Inc. 4.8. ZOOM L A NE 1 It is setting fo r Step Zoom opti on. (Not appli cable to Dual Lane) Location: Menu  Settings  Syste mSettings  ZOOMLANE1 4.8.1. ZOOM LANE 1 1. Zoom Fir…

100%1 / 67
56
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
Compensation Option
It is to set the compensation algorithm when Multi Fiducial inspection.
1. Z MOVE
0. Dont Use: Used for the inspection with Multi Fiducial + Auto Scale factor. Z_Move is
not used. (Used when the warpage is not severely seen.)
1. Use: Used for the inspection with Multi Fiducial + Auto Scale factor + Z_Move
(Used when the warpage is severely seen)
2. Z MAP EXPORT
1. Use: When Multi + Auto Scale factor + Z_Move inspection are finished, PCB Z_Map .csv
file can be exported.
Path: C:\Kohyoung\KY-3030
3. Method: Compensation method
0. Normal: Using the shortest distance scale for warpage compensation
1. Plane Surface: Using the horizontal plane for warpage compensation
2. Avg Comp: Using the neighbor height of FOV for average warpage compensation
3. Spline Comp: Using B-Spline for warpage compensation
4. Spline + Plane: Using the horizontal plane & Spline for warpage compensation
4. FID RETRY:
This is a function to compensate warpage using Fiducial Z axis compensation. When the
warpage occurs at the fiducial position, it compensates it to the focusing position.
(maximum 3 times retry)
0. Dont Use: The function of Fiducial Retry is not used.
1. Use: The function of Fiducial Retry is used.
57
Service Manual
Koh Young Technology Inc.
4.8. ZOOM LANE 1
It is setting for Step Zoom option. (Not applicable to Dual Lane)
Location: Menu Settings SystemSettings ZOOMLANE1
4.8.1. ZOOM LANE 1
1. Zoom First~Fifth Position
Head Position: Head Axis focusing value of Zoom Position
LENS Position: Lens Axis focusing value of Zoom Position
OFFSET X: In case of Mix Job File, Camera Offset X value when it moves to other step from
default step.
OFFSET Y: In case of Mix Job File, Camera Offset Y value when it moves to other step from
default step.
2. STEP ZOOM MODE
StepZoom Comport Setting
3. ZOOM STROKE(Unit:mm)
It is to set the max stroke value of Head, Lens Axis.
58
WinMCS_Manual(ENG) rev1.0
Koh Young Technology Inc.
5. TOWER LAMP SETTING
It is setting for Lamp On/Off and alarm for each machine mode.
5.1. TOWER LAMP SETTING