00197394-03_AI_Smart-Pin-Support_X-S_DE_EN.pdf - 第104页

3 Installation 3.3 Installing the W5 magazine (SIPLACE X3 S, X4 S) 104 Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 3.3 Installing the W5 magazine (SIPLACE X3 S, X4 S) See also 2 …

100%1 / 126
3 Installation
3.2 Installation of Pin PIcker
Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 103
3.2.4 Connecting the Compressed Air Supply
Connection of the compressed air supply can differ, depending on the head which is fitted.
CAUTION
Cable and hose path
Make sure that the entry areas for the gantry buffer are kept free of cables and hoses.
These could be trapped otherwise.
Use the pneumatic connection at the top right, on the compressed air distributor, par-
ticularly when a vacuum pump is fitted. There may not always be a compressed air
supply at other connections.
Connecting compressed air to a gantry with SIPLACE Twin
Fig.26: Connecting the compressed air with SIPLACE Twin
Connect the pneumatic hose(1) for the
pin picker to the top right connection(2)
on the compressed air distributor. You
may need to use a T or Y piece for this.
Shorten the hoses to suitable lengths
for this.
Fix the hose with cable ties.
Connecting compressed air to a gantry with SIPLACE C&P/CPP
Fig.27: Compressed air with SIPLACE C&P/CPP
Connect the pneumatic hose(1) for the
pin picker to the top right connection(2)
on the compressed air distributor.
Shorten the hoses to suitable lengths
for this.
Fix the hose with cable ties.
3 Installation
3.3 Installing the W5 magazine (SIPLACE X3 S, X4 S)
104 Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019
3.3 Installing the W5 magazine (SIPLACE X3 S, X4 S)
See also
2 2.4 "Possible Configurations/Required Equipment" [}82]
3.3.1 Preparatory Steps
The "Row 2 nozzle changer" option must be installed.
If required, dismantle the row 1 nozzle changer for easier access. Read the service manual
for your machine for more information, if required.
3.3.2 Checking/Correcting the Vertical Distance
If you have not already done so, you need to check the height of the second NC row.
For better access when measuring on the outer side, push the placement head inwards.
Move the gantry so that the placement head is roughly on the planned NC position.
NOTICE
Avoid scratching the magnetic strip.
Make sure that the tip of the measuring scale does not touch the magnetic strip, as this
might scratch it!
Checking the height of the second NC row
Fig.28: Height check (using the example of the holder for
second NC row)
Check the height of the installed sup-
ports or holders for the second row.
Position the measuring scale vertically
onto the top edge of the X axis lower
linear guide at (1) and measure the dis-
tance to the support or holder contact
surface (2).
Measured value: 150.0mm +/‑0.2mm
If the distance is smaller, you will need
to remove the shim plates from under
the contact surfaces and repeat the
measurement.
Checking the height of the ASP support
Fig.29: Checking the height of the ASP support (using
example of SIPLACE X3 S/X4 S representing the measuring
principle)
If the height of the second NC row is cor-
rectly set to 150.0mm +/- 0.2 mm, you will
need to check the distance between the NC
and the ASP support.
Position the measuring scale vertically
onto the contact surface of the NC (1)
and measure down to the ASP support
(2).
Measured value: 77mm +/‑0.2mm
If the distance is outside the tolerance
range, insert or remove shim plates as
required.
3 Installation
3.3 Installing the W5 magazine (SIPLACE X3 S, X4 S)
Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 105
3.3.3 Connecting the "Magazine Recognition" Board (If Present)
NOTICE
From SW 706.1 SP2
Configuration of the magazines is performed automatically in machines before SW
706.1 SP2, using the "magazine recognition" board.
If older machines with SPS are upgraded to a version equal to or higher than SW
706.1 SP2, the existing magazine configuration is kept in the software. If additional
magazines without board are fitted into these upgraded machines, these must be
manually configured via the software (Autoconfig).
From SW 706.1 SP2, magazines can be fitted without the "magazine recognition"
function. In this case, the machine can only be configured manually via the software
(Autoconfig).
Proceed with chapter 3.3.4 "Assembling the W5 magazine" [}106] if this applies.
Fig.30: Data cable for NC 2 and SPS
Locate the required cables.
Four labeled data cables have been pre-
pared in the machine for the various config-
urations of NCs with and without Smart Pin
Support (SPS).
X1*a (NC 1)
X1*b (SPS (1) or NC 2 (without SPS))
X1*c (NC 2 with SPS)
X1*d (SPS2)
Fig.31: Board connection (using example of Q10)
If not fitted, screw the board to the un-
derside of the magazine with four
M2.5x4 screws. The connection for the
flat ribbon cable should point towards
the angular metal bracket(4).
Connect the power supply cable (1) to
connector X8 on the magazine board.
Fit the strain relief for the voltage sup-
ply cable to the metal bracket and then
fix the cable into place.
Connect the "NC SPS ribbon cable" (2)
to connector X6 on the board and
screw into place.
Set the jumper (3) on the DIP
switchS1. (see below )