00197394-03_AI_Smart-Pin-Support_X-S_DE_EN.pdf - 第96页
2 Brief Description 2.8 Required Working Time 96 Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019

2 Brief Description
2.7 Tools and Equipment Required
Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 95
2.7 Tools and Equipment Required
●
Standard tooling
●
Torque screwdriver 100-500 Ncm [03078400-xx]
●
Depth measuring gauge 300mm [03079617-xx] (recommended)
or
Standard measuring gauge (slide gauge)
NOTICE
Q10 magazine
To install the Q10 magazine, you need a depth measuring gauge. A standard measuring
gauge does not cover the required measuring range of over 227 mm.
●
For each pin picker: 5x cable ties W=2.4mm L=92mm TYB-23M "black" [00805140-xx]
●
For each pin picker: 1x mounting base MB1 [00362777-xx]
●
For each pin picker: 1x DIN7991-M3x6-A2 screw [03016240-xx]
●
Loctite 243 [00334892‑xx]
●
Service manual for your machine
●
If necessary: Assembly instructions "Row 2 Nozzle Changer – Nozzle Changer Before
MTC" [DE+EN:00197369‑xx]
●
If required, "Operating and Configuring the Smart Pin Support SX" user guide [00197001-xx].
2.8 Required Working Time
The complete hardware installation takes 3 to 4 hours, depending on the machine type.
Programming work on the SIPLACE Pro computer may also be needed.

2 Brief Description
2.8 Required Working Time
96 Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019

3 Installation
3.1 Preparatory Steps
Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 97
3 Installation
This section describes the following topics:
●
Preparatory steps
●
Installing the pin picker
●
Installing the W5 magazine
●
Installing the Q10 magazine
●
Converting the nozzle station and the reject bin
●
Inserting the dummy feeder
●
Final work
These tasks need to be performed at each gantry or each location, depending on the configuration.
NOTICE
From SW 706.1 SP2
From SW 706.1 SP2, magazines can be fitted without the "magazine recognition" function.
In this case, the machine can only be configured manually via the software (Autoconfig).
3.1 Preparatory Steps
► SIPLACE X3 S, X4 S:
If not already present, you need to fit a "row 2 " nozzle changer. For details, read the assem-
bly guide "Row 2 Nozzle changer – Nozzle Changer Before MTC" [00197369-xx].
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}75]