00197394-03_AI_Smart-Pin-Support_X-S_DE_EN.pdf - 第73页

1 Introduction 1.1 Safety Instructions Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 73 1.1.5 Safety instructions for the compressed air supply CAUTION Risk of injury from compress…

100%1 / 126
1 Introduction
1.1 Safety Instructions
72 Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019
Machine switched off at the main switch, but still connected
DANGER
Risk of death by voltages!
Death, serious injury or considerable damage may result if these machines are handled
incorrectly.
The following components still carry potentially lethal voltages on the power supply even if
the main power switch is switched off:
Main power supply cable connection terminals
L1, L2, and L3 of the main switch S1
Service socket X98 (if present)
The contactor safety breaker (CBS) still carries voltage for five minutes after switching
off at the main switch.
The color of all individual wires which still carry potentially lethal voltages even if the
main power switch is switched off is orange.
Fig.1: Power supply unit (SIPLACE X-SeriesS, SMPS)
1. Main switch (S1)
2. Main power supply cable connection ter-
minals (X95) for the power supply cable
3. Service socket X98
(if present)
Machine switched off at the main power switch and disconnected
DANGER
Hazardous voltages in the power supply unit!
The power supply unit houses components (capacitors) that can carry hazardous voltages
for about five minutes after the machine has been switched off and the power plug has
been unplugged.
Wait at least five minutes before your start working on the power supply unit.
Work on the power supply and the contactor safety breaker (CSB) must only be car-
ried out by service engineers of ASM Assembly Systems GmbH & Co. KG or by
machine owner service engineers who have been trained by ASM.
Compressed air conditions in the machine after switching off at the main switch
When the machine is switched off at the main power switch or if the power supply fails, the electric-
ally-controlled main valve of the compressed air unit closes. The pressure will drop to 0 MPa
(0bar) within five seconds.
1 Introduction
1.1 Safety Instructions
Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019 73
1.1.5 Safety instructions for the compressed air supply
CAUTION
Risk of injury from compressed air!
Risk of injury when disconnecting the compressed air lines.
Never disconnect compressed air lines while they are still pressurized.
CAUTION
Prolonged interruptions to the compressed air supply can cause damage.
When the machine is switched on, do not use the shutoff valve to interrupt the compressed
air supply for more than 30 minutes.
If you need to shut off the compressed air system for longer in order to carry out your
work, you must switch the machine off at the main switch and disconnect it from the
power supply.
1.1.6 Safety instructions for the gantry
CAUTION
Moving the gantry can damage the placement head.
When moving the gantry, observe the following:
NEVER move the gantry by pushing with your hands against the placement head.
NEVER push the gantry while the Z axis is lowered.
1.1.7 Safety instructions for maintenance tasks
WARNING
Danger of burning
Never use inflammable fluids (e.g. alcohol) for cleaning purposes when working in the
vicinity of a naked flame or fire.
Never spray lubricants or cleaning agents from aerosol cans in the vicinity of a naked
flame or fire.
CAUTION
Ethanol
Always wear safety goggles and gloves when using concentrated ethanol to clean
modules.
If ethanol should accidentally get into your eyes, rinse your eyes immediately with wa-
ter.
1 Introduction
1.1 Safety Instructions
74 Assembly Instructions / Montageanleitung SIPLACE X-Series S Smart Pin Support 05/2019
Fig.2: Cleaning wipe
 CAUTION!
Cleaning wipe
Harmful: may cause lung damage if
swallowed.
Do not inhale vapor / aerosol.
Avoid contact with the skin. If swal-
lowed, do not induce vomiting. See
medical attention immediately and
show the packaging or label.
Wear latex gloves while using the
cleaning tissue.
.
CAUTION
Consumables
Observe the safety data sheets for consumable materials!
CAUTION
Cleaning and lubrication
Always use ethanol for cleaning – do not use solvents.
Isopropanol – IPA can be used as an alternative.
NEVER use compressed air to clean units inside the placement machine or modules.
CAUTION
Danger of cutting on the IC and FC camera
There is a risk of cutting your fingers along the edges of the mirror.
Wear laboratory gloves as protection and avoid touching the edges.
The laboratory gloves are also required for effective cleaning (fingerprints!).
CAUTION
Only one person must be present at each component preparation station at any
given time.
This is to ensure the safety of the operator and the safety of the second person. Pulling in
the component trolley is a two-handed operation, so only one person can be reliably protec-