4 Electrical Section
4-28
Control Board
Handling Control Board
Note the followings when handling PC boards.
z Do not touch control boards by wet hands.
z Do not handle control boards where there are metal chips around.
z Wear an antistatic wrist strap and connect it with any metal part of the machine.
z Do not put an electrical board on the place where may cause the short circuit.
4 Electrical Section
4-29
Adjustment of Board Detection Sensors
This section explains how to adjust the sensitivity of the board detection sensors.
LE6-M6547-00X PHOTO SENSOR E3Z-LS81 (OMRON
z Entrance sensor
z Exit sensor
z Exit buffer arrival sensor
Adjusting Method
Place a PCB on the conveyor belt in the direction in which PCBs will be placed for actual production
operation.
Turn the sensor’s sensitivity volume counter-clockwise (toward “min”) as far as it will go, to set the
sensitivity to the minimum level.
*The volume can be turned 3/4 turns. Turning it clockwise (toward “max”) increases the sensitivity
and turning it counter-clockwise (toward “min”) decreases it.
With the PCB detected by the sensor, turn the volume clockwise (toward “max”) gradually, up to the
point (A) where the orange LED (operation indicator) begins to light up.
Remove the PCB and turn the volume clockwise (toward “max”), up to the point (B) where the orange
LED begins to light up. (If the orange LED does not light up even if the volume is turned clockwise as
far as it will go, the position to which the volume has been turned clockwise as far as it will go will be
considered to be position (B).)
The center position between the positions (A) and (B) is set as the adjustment position. With the PCB
detected at that position, check that both orange and green LEDs light up at the same time. Also check
that only the green LED lights up when the PCB is removed.
When the conveyor cover is provided because of the safety spec., attach a black rubber sheet
(LG0-M9AA1-00X GOM) to the sensor detection position on the bottom of the cover to prevent false
detection.
NOTE: Make sure that the operation selector switch is set to “L” (ON when light is entered).
max min
DL
Sensor emitting direction
Enlarged View of Sensor
(Shown in upside down direction)
Operation indicator
(Orange LED)
Operation-stable
indicator
(Green LED)
Sensitivity volume
Operation selector switch
4 Electrical Section
4-30
LC2-M912A-01X PHOTO SENSOR WTV4-3P1321S54 (SICK)
z PCB arrival sensor
z Entrance buffer arrival sensor
Adjusting Method
Use a precision flat-blade screwdriver to turn the sensitivity volume counter-clockwise as far as it will
go, to set the sensitivity to the minimum level. Place a PCB on the conveyor belt in the direction in
which PCBs will be placed for actual production operation, transfer it to a position just over the arrival
sensor, and turn the sensitivity volume clockwise until the sensor’s receiver indicator lights up.
NOTE: The sensitivity volume can be turned approx. five turns between the maximum and minimum level
positions. When the volume is beyond the maximum or minimum level position, a ratchet will be activated
and the volume turns freely with a chattering sound. The position at which such sound is heard is the limit
of the adjustable range.
With the PCB placed on the conveyor belt, move it just above the arrival sensor back and forth a few
times by hand, to check that the receiver indicator turns ON and OFF in response to the PCB.
NOTE: The receiver indicator has three states: ON = stable operation, OFF = no sensitivity, Blink = unstable
operation. When adjusting the volume or checking sensor’s response to the PCB, make sure that the
indicator is not blinking.
From position (2), turn the volume 1/4 turns (90 degrees) clockwise to increase the sensitivity.
For verification, select [Manual] – [PCB Sensors ] to open the [PCB Sensors ] window. Check that the
PCB arrival sensor/entrance buffer arrival sensor respond to the PCB correctly. Also select [Manual]
– [Load Board ] to check that the PCB is automatically clamped properly.
NOTE: If the sensitivity is set excessively high, a malfunction may occur when the head passes over the arrival
sensor.
Receiver
indicator
Emitter/receiver
Sensitivity volume
Lower
sensitiv
Higher
sensitiv
Sensitivity Adjustment
by Volume