3 Mechanical Section 3-18 ■ Securing the syringe While pulling the valve' s moving part forward, press the syrin ge joint into th e adapter base. Press in until a latching sound (click) is heard. Tighten the finger …

3 Mechanical Section
3-17
■ Connecting the tube joint and syringe
■ Connecting to the valve
Screw the tube joint in clockwise.
Use care to avoid stripping the threads.
Insert until a latching
sound (click) is heard.
Rotate the lug in the clockwise direction
to lock it.

3 Mechanical Section
3-18
■ Securing the syringe
While pulling the valve's moving part
forward, press the syringe joint into the
adapter base.
Press in until a latching sound (click) is heard.
Tighten the finger screw to secure the syringe.

3 Mechanical Section
3-19
■ Installing the DP head on the nozzle holder
■ Dispense setting
Manual > Dispense
* When installing the DP head, be sure to specify the settings for the installed DP head and syringe.
* If unable to press it all the way to the rear,
slightly shift the screw pump shaft and
hexagon phase.
Install the screw's lock screw.
Use the accessory torque wrench to tighten.
LE6-M5W22-100 /WRENCH,14-5NM
Use the accessory torque wrench to tighten.
LE6-M5W22-100 /WRENCH,14-5NM
Right-click here to select the dispense head type.
Right-click here to select the syringe type.
* If the desired type is not in the library, create a
syringe library.