3 Mechanical Section 3-2 Head Manifold Section Air Filter Cap Supply Valve LE6-M71A2-B0X Breaking Valve LE6-M71A2-C0X Solenoid Valve (4 pieces)

100%1 / 120
3 Mechanical Section
3-1
3
Mechanical Section
3 Mechanical Section
3-2
Head Manifold Section
Air Filter Cap
Supply Valve
LE6-M71A2-B0X
Breaking Valve
LE6-M71A2-C0X
Solenoid Valve (4 pieces)
3 Mechanical Section
3-3
Head Manifold Section
Air Passage
To maintain the designed accuracy and component-placement rate of the machine, clean the air passage
between the air filter assy. and nozzle holder periodically.
ACTION: Carry out vacuum break operation for a few seconds with the nozzle removed.
Cleaning interval
Approx. once a week
Air Filter
ACTION: Remove a filter element from an air filter assy. and remove dust and dirt collected inside the assy. by air
blowing. Then, check the white air element for dirt. If it is excessively dirty, replace it with a new one.
If an O-ring attached on the filter cap gets dirty, wash it with water or diluted neutral detergent, and dry it
well. If there are cracks on the o-ring, replace it with a new one since the cracks may cause air leakage.
Inspection interval
Once a week, and when a choking error occurs
Part Name
Part No. Remark
FILTER LE6-M71A2-E0X Filter element
Vacuum Generator
ACTION: Breakdown Visually check the silencer element, and if it is excessively dirty, replace it with a new one.
Also measure the maximum air pressure to inspect whether the vacuum generator can generate vacuum
properly.) Inspection for Head/Nozzle Clogging and Solenoid Valve
Inspection interval
Once a week