4 Electrical Section 4-3 ■ Motor tab ■ Motor Sensor tab Window: ALM: Alarm MEL: Minus End Limi ted PEL: Plus End Limite d MARK: Mark INP: In Position MSLD: Minus Sl ow Down PSLD: Plus Slow Down EZ: 0 Phase ORG: Origin

4 Electrical Section
4-2
Signal I/O
Signal I/O is the abbreviation of signal input/output. The signal input refers to the input signal via the
sensors. The signal output refers to the command transmitted to the actuators.
Signal Output (Control) window serves as controls to move actuators for checking their movements. In
response to their movements, Signal Input (Monitor) window shows On/Off of motors and actuators.
Signal Input Monitor
You can check On/Off of the sensors real-time. “1” indicates on, “0” off. When a sensor of a switch, motor,
and actuator responds, the change of the sensor status is shown real-time. Wire disconnection or sensor
failure can also be detected.
Menu: Manual>Signal I/O>Signal Input (Monitor)
Signal Input (List) ・・・Not Use
Signal Input (Details)・・・Not Use
FIO ・・・・・・・・・・ Not Use

4 Electrical Section
4-3
■ Motor tab
■ Motor Sensor tab
Window:
ALM: Alarm
MEL: Minus End Limited
PEL: Plus End Limited
MARK: Mark
INP: In Position
MSLD: Minus Slow Down
PSLD: Plus Slow Down
EZ: 0 Phase
ORG: Origin

4 Electrical Section
4-4
Signal Output Control
The Signal Output (Control) window serves as controls to turn on or off actuators. “1” in the window
indicates On state, “0” Off state. “0” and “1” toggle as you click on it, and the corresponding actuator is
turned on or off simultaneously. This operation allows you to check actuator movement in troubleshooting.
When an actuator moves properly in this operation, its sensor responds and the Signal Input (Monitor)
window shows the real-time result. The combination of an address and bit number (0-7) represents a signal.
The name of each signal is shown in the Details tab.
Turning on/off signal output in the Signal Output (Control) window allows an actuator to move. When
executing this operation, do not stick head, hands, or other parts of the body inside the unit. Serious injury
can result. Also make sure non-operators are a safe distance from the unit.
Before performing signal output on/off operation, make sure no foreign obstacles are left in the unit or tray
feeder. Otherwise, costly machine damage can occur.
Menu: Manual>Signal I/O>SignalOutput(Control)
■Digital Output (List) ・・・Not Use
■Digital Output (Details)・・・Not Use
Warning