DEUKYX-193-6100_G5S2_VOL6.pdf - 第39页

DEUKYX 2-15 193-6100 1.4 Control Data (Überwachungsdaten) 1.4 Control Data (Überwachungsdaten) Liste der „Control Data” : Pro Aufnehmer ( „SIGMA-G5SII Series“ Register- blattes) N r. Datenname Ref.-Nr . 1 Selected nozzle…

100%1 / 190
DEUKYX
2-14193-6100
1.3 Recognition Data (Erkennungsdaten)
1.3.4 Weiteres
Liste der „Recognition Data” (Erkennungsdaten)
Nr. Datenname
Component
Shape
Ref.-Nr.
Special
1 Lighting system
(C01_01)
2 Recognition data set
(C01_02)
3 Recognition level
(C01_03)
4 Back ltg recog algo,
Front ltg recog algo
(C01_04)
11 Lighting pattern
(C01_11)
(1) Back ltg
(2) Front ltg 3-1 (Ring (Up - Up))
(3) Front ltg 3-2 (Ring (Up - Dn))
(4) Front ltg 2 (Coax)
(5) Front ltg 1-1 (Ring (Dn - Up ))
(6) Front ltg 1-2 (Ring (Dn - Mid ))
(7) Front ltg 1-3 (Ring (Dn - Dn ))
12 Lighting method
(C01_23)
13 Extended lighting
(C01_24)
Extended lighting pattern Back Itg
Extended lighting pattern Front Itg 3-1 (Ring (Up-Up))
Extended lighting pattern Front Itg 3-2 (Ring (Up-Dn))
Extended lighting pattern Front Itg 2 (Coax)
Extended lighting pattern Front Itg 1-1 (Ring (DN-Up))
Extended lighting pattern Front Itg 1-2 (Ring (DN-Mid))
Extended lighting pattern Front Itg 1-3 (Ring (DN-Dn))
14 Image capture method
(C01_12)
15 FOVspecication
(C01_13)
16 Shape pos detn Shape pos tol [mm]
(C01_25)
22 Reverse Check
(C01_22)
(1) Image capture
(2) Lighting pattern
Back ltg
Front ltg 3-1 (Ring (Up - Up))
Front ltg 3-2 (Ring (Up - Dn))
Front ltg 2 (Coax)
Front ltg 1-1 (Ring (Dn - Up ))
Front ltg 1-2 (Ring (Dn - Mid ))
Front ltg 1-3 (Ring (Dn - Dn ))
(3) Method
(4) Mode
(5) Inspection pos X [mm], Y [mm]
(6) Inspection range X [mm], Y [mm]
(7) Surface specication
(8) Surface image
DEUKYX
2-15193-6100
1.4 Control Data (Überwachungsdaten)
1.4 Control Data (Überwachungsdaten)
Liste der „Control Data” : Pro Aufnehmer
(
„SIGMA-G5SII Series“
Register-
blattes)
Nr. Datenname Ref.-Nr.
1
Selected nozzle #1
(D01_01)
(1) Nozzle ID
(2) Control command
(3) Pu retention time [sec]
(4) Pl retention time [sec]
(5) Speed data Beam (X/Y) [%]
(6) Speed data Pu dclr Descent 1 [%]
(7) Speed data Pu dclr Descent 2 Setting
(8) Speed data Pu dclr Descent 2 [%]
(9) Speed data Pu dclr Descent 2 Stroke [mm]
(10) Speed data Pu dclr Ascent 1 [%]
(11) Speed data Pu dclr Ascent 1 Stroke
[mm]
(12) Speed data Pu dclr Ascent 2 [%]
(13) Speed data Pu dclr X Setting, Y Setting (Reserviert)
(14) Speed data Pl dclr Descent 1 [%]
(15) Speed data Pl dclr Descent 2 Setting
(16) Speed data Pl dclr Descent 2 [%]
(17) Speed data Pl dclr Descent 2 Stroke [mm]
(18) Speed data Pl dclr Ascent 1 [%]
(19) Speed data Pl dclr Ascent 1 Stroke [mm]
(20) Speed data Pl dclr Ascent 2 [%]
(21) Speed data Pl dclr X Setting, Y Setting (Reserviert)
(22) Speed data Nozzle rotation [%]
(23) Nozzle selection (NS dclr) [%]
(24) Cmpnt detection (Sensor)
(25) Pick-up noz angle [deg]
(26) Air blow
(27) Air blow off timing [mm]
(28) Placement conrmation (Reserviert)
(29) Flow detection
2 Selected nozzle #2
Selected Nozzle: Same as Nozzle #1
(D01_02)
3 Selected nozzle #3
Selected Nozzle: Same as Nozzle #1
(D01_03)
DEUKYX
2-16193-6100
1.4 Control Data (Überwachungsdaten)
Liste der „Control Data” („SIGMA Series Common“ Registerblattes)
Nr. Datenname Ref.-Nr.
4
Control Mode
(D01_04)
5
Cmpnt pos correction X [mm], Y [mm]
(D01_05)
6
Pick-up pos correction X [mm], Y [mm]
(D01_06)
7
Auto fdr axis adjustment X, Y
(D01_07)
8
Error process 1
(D01_08)
9
Error process 2
(D01_09)
10
Vertical Cmpnt data [mm]
(D01_10)
11
Pick-up level [mm]
(D01_11)
12
Placement level [mm]
(D01_12)
13
Focus adjustment [mm]
(D01_13)
14
Tape feed dclr [%]
(D01_14)
15
Collection after interlock
(D01_15)
16
Rejected cmpnt disch pos
(D01_16)
17
Placement height feedback
(D01_17)
18
Cmpnt thickness check [mm]
(D01_18)
19
Capture mode
(D01_19)
20
Pressure insert operation
(D01_20)
Loading limit [N]
Cmpnt clinch position check
Pressure insert check
21
Pick-up loading limit
(D01_21)
22
Splicing supply
(D01_22)
Tape feed dclr for joint [%]
Auto skip for joint
23
Pick-up difference detn X, Y, und Angle
(D01_23)
Pick-up difference tol X [mm], Y [mm]
and Angle [deg]
24
Reverse Check (Sensor)
Reserviert
Threshold [%]
25
Placement angle recognition
Reserviert
26
Layer No.
(D01_26)
27
Placementoffsetspecication
(D01_27)
28
Component pushing operation
(D01_28)
29
Comp Drop detection
(D01_29)
30
Tape pocket position detection
(D01_30)
31
LCR Check
Reserviert