DEUKYX-193-6100_G5S2_VOL6.pdf - 第40页
DEUKYX 2-16 193-6100 1.4 Control Data (Überwachungsdaten) Liste der „Control Data” („SIGMA Series Common“ Registerblattes) N r. Datenname Ref.-Nr . 4 Control Mode (D01_04) 5 Cmpnt pos correction X [mm], Y [mm] (D01_05) 6…

DEUKYX
2-15193-6100
1.4 Control Data (Überwachungsdaten)
1.4 Control Data (Überwachungsdaten)
Liste der „Control Data” : Pro Aufnehmer
(
„SIGMA-G5SII Series“
Register-
blattes)
Nr. Datenname Ref.-Nr.
1
Selected nozzle #1
(D01_01)
(1) Nozzle ID
(2) Control command
(3) Pu retention time [sec]
(4) Pl retention time [sec]
(5) Speed data Beam (X/Y) [%]
(6) Speed data Pu dclr Descent 1 [%]
(7) Speed data Pu dclr Descent 2 Setting
(8) Speed data Pu dclr Descent 2 [%]
(9) Speed data Pu dclr Descent 2 Stroke [mm]
(10) Speed data Pu dclr Ascent 1 [%]
(11) Speed data Pu dclr Ascent 1 Stroke
[mm]
(12) Speed data Pu dclr Ascent 2 [%]
(13) Speed data Pu dclr X Setting, Y Setting (Reserviert)
(14) Speed data Pl dclr Descent 1 [%]
(15) Speed data Pl dclr Descent 2 Setting
(16) Speed data Pl dclr Descent 2 [%]
(17) Speed data Pl dclr Descent 2 Stroke [mm]
(18) Speed data Pl dclr Ascent 1 [%]
(19) Speed data Pl dclr Ascent 1 Stroke [mm]
(20) Speed data Pl dclr Ascent 2 [%]
(21) Speed data Pl dclr X Setting, Y Setting (Reserviert)
(22) Speed data Nozzle rotation [%]
(23) Nozzle selection (NS dclr) [%]
(24) Cmpnt detection (Sensor)
(25) Pick-up noz angle [deg]
(26) Air blow
(27) Air blow off timing [mm]
(28) Placement conrmation (Reserviert)
(29) Flow detection
2 Selected nozzle #2
Selected Nozzle: Same as Nozzle #1
(D01_02)
3 Selected nozzle #3
Selected Nozzle: Same as Nozzle #1
(D01_03)

DEUKYX
2-16193-6100
1.4 Control Data (Überwachungsdaten)
Liste der „Control Data” („SIGMA Series Common“ Registerblattes)
Nr. Datenname Ref.-Nr.
4
Control Mode
(D01_04)
5
Cmpnt pos correction X [mm], Y [mm]
(D01_05)
6
Pick-up pos correction X [mm], Y [mm]
(D01_06)
7
Auto fdr axis adjustment X, Y
(D01_07)
8
Error process 1
(D01_08)
9
Error process 2
(D01_09)
10
Vertical Cmpnt data [mm]
(D01_10)
11
Pick-up level [mm]
(D01_11)
12
Placement level [mm]
(D01_12)
13
Focus adjustment [mm]
(D01_13)
14
Tape feed dclr [%]
(D01_14)
15
Collection after interlock
(D01_15)
16
Rejected cmpnt disch pos
(D01_16)
17
Placement height feedback
(D01_17)
18
Cmpnt thickness check [mm]
(D01_18)
19
Capture mode
(D01_19)
20
Pressure insert operation
(D01_20)
Loading limit [N]
Cmpnt clinch position check
Pressure insert check
21
Pick-up loading limit
(D01_21)
22
Splicing supply
(D01_22)
Tape feed dclr for joint [%]
Auto skip for joint
23
Pick-up difference detn X, Y, und Angle
(D01_23)
Pick-up difference tol X [mm], Y [mm]
and Angle [deg]
24
Reverse Check (Sensor)
Reserviert
Threshold [%]
25
Placement angle recognition
Reserviert
26
Layer No.
(D01_26)
27
Placementoffsetspecication
(D01_27)
28
Component pushing operation
(D01_28)
29
Comp Drop detection
(D01_29)
30
Tape pocket position detection
(D01_30)
31
LCR Check
Reserviert

DEUKYX
2-17193-6100
1.5 Carrier Data (Trägerdaten)
1.5 Carrier Data (Trägerdaten)
Liste der „Carrier Data”
Nr. Datenname
Bauteilträger
Ref.-Nr.
Papier
Erhaben
Tray
Vibration
Stange
1 Carrier data
(E01_01)
(1) Type
Paper Embossed Tray
Vibratory
Stick
(2) Tape width [mm]
⃝ ⃝
-
⃝
(3) Tape feed pitch [mm]
⃝ ⃝
- -
(4) Usage Tray - -
●
-
(5) Direction [deg]
⃝ ⃝ ⃝ ⃝
(6) Pick-up angle [deg]
⃝ ⃝ ⃝ ⃝
(7) Q'ty
⃝ ⃝
-
⃝
(8) Single usage
⃝ ⃝
- -
(9) Feeder Type(Standard/SL)
⃝ ⃝
- -
(10) Feeder type
⃝ ⃝
- -
Tape end detection
⃝ ⃝
- - (E01_02)
Magnetic Type
⃝ ⃝
- - (E01_03)
High Speed Feed
⃝ ⃝
- - Reserviert
Teaching motion
-
⃝ ⃝
- (E01_04)
2 Tray data
(E01_05)
(1) Matrix X, Y - -
●
-
(2) Height h [mm], H [mm] - -
●
-
(3) Side length X [mm], Y [mm] - -
●
-
(4) Pitch X [mm], Y[mm] - -
●
-
(5) Xfr speed - -
●
-
(6) Elevator speed
●
-
(7) Matrix missing - - Reserviert -
3 Stick data
(E01_06)
(1) Stick width [mm] - - -
⃝
(2) Feed time [sec] - - -
⃝