1-52 0709-001 4.4 Procedure of Flat Ring Replacement T ime of Replacement It is recommended that they should be replaced every 3 months (approx.). Replacement Procedure Procedure (1) Zero the cutter . Reference Refer to …

1-51
0709-001
(9) Loosenthescrewsoftapeguideanddetachthe
uorinesheet
andtheplate.Afterthat,replace
theuorinesheetwithanew
one.
Tape Guide
New Fluorine Sheet
Old Fluorine Sheet
Fig. 4A50
(10)Attachtheuorinesheetandtheplatetothetapeguide.
At this time, conrm that the uorine sheet is put between the tape
clamps.
(1
1)Detachthecutunitxingjig.
(12) Attach the tape guide and the transparent cover.
(13)
Close the cover, power the machine, and perform a zeroing
operation.
(14) Select the [Round trip] button in the "Mode" group box in the
"CUTTER ADJ" window to shuttle the cutters.
(OperationSequence:[MAINT]onMainMenu
→[UNITADJ.]
on
SubmenuBar→"CUTTERADJ"window)
The unrequired portions of the uorine sheet are cut and fall down into
the scrap box of the bank feeder change cart.
Notice
Besuretocuttheunrequiredportionsoftheuorinesheetwithout
the tape being threaded through the cutters. Otherwise, the tape
cannot be cut normally.
4.3 Replacement of Fluorine Sheet and Urethane Clamp

1-52
0709-001
4.4 Procedure of Flat Ring Replacement
Time of Replacement
It is recommended that they should be replaced every 3 months (approx.).
Replacement Procedure
Procedure
(1) Zero the cutter.
Reference
Refer to "4.4 "CUTTER ADJ" Window" in "Chapter 4 (Vol. 2)" for
the zeroing operation of the cutter.
(2) Move down the feeder base and detach the bank feeder change
cart.
(3) Turn off the power to the machine.
(4) Open the cover.
(5) Detach the transparent cover (origin and motor sides) and the
tape guide.
Notice
(a) Carefully detach or attach the tape guide to avoid the
Y-axis linear scale being scratched.
(b) When the cutter is not located at its origin, the tape guide
cannotbedetachedbecausetheuorinesheetiscaught
by the tape clamp.
Tape Guide
Transparent Cover
(Motor Side)
Transparent
Cover
(Origin Side)
Fig. 4A51
4.4 Procedure of Flat Ring Replacement

1-53
4.4 Procedure of Flat Ring Replacement
(6) Usetheinnerholesofthecutunitxingjigwiththetapeclamp
being closed and attach the jig with the bent portion being
directed upward.
Fig. 4A52
WARNING
Pay close attention to the cutter blade during the maintenance
work.
•
Lack of attention will result in a hand injury, etc.
Wear gloves and take the greatest care in performing the work.
•
Besuretoattachthexingjigtothecutunitduringthe
maintenance work for safety purposes.
(7) Cuttheusedatringwitha
cutteronmarketanddetachit.
(8) Attachtheatringtotheatringreplacementjig.
Fig. 4A53
0802-002