4OM-1431-006_w.pdf - 第171页

3-14 0709-001 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 421 101 Input Buffer Cnvr . Overtime P .C.B. from inp. Machine was not received. Please continue the work after checking the P .C.B on a conv…

100%1 / 271
3-130709-001
3.3 Conveyor
3.3 Conveyor
Table 4C5
Erroe ID Error Name, Description, Cause, and Remedy
420701 P.C.B Stopper
It is set as "Use" of a positioning stopper in the system data, and the stopper
cannotbeconrmedonadevice.
Pleaseconrmthat
astopperworksaccurately.
420702 P.C.B Stopper
It is set as "Use" of a reversal positioning stopper in the system data, and the
stoppercannotbeconrmedonadevice.
Pleaseconrm
thatastopperworksaccurately.
420801 Manual transfer error
When operation started, error was detected.
-----
420802 Manual transfer error
Error was detected while operating.
-----
420803 Manual transfer error
Operation did not end in prescribed time.
-----
420901 Transfer Error (Others)
Please check the PCB on each conveyer.
-----
420902 Transfer Error (Others)
An error for timeout occurred in communication process during transfer process
startup.
Restart the operation.
420a01 Chute Clamp
It failed to release the chute clamp before NB-W axis operation. (Stage1)
Perform
theoperationagain.Ifthefailureoccurs
repeatedly,pleaseconrmthe
chute clamp pressure sensor.
420a03 Chute Clamp
It failed to release the chute clamp before NB-W axis operation.
Performtheoperationagain.Ifthefailureoccurs
repeatedly,pleaseconrmthe
chute clamp pressure sensor.
3-140709-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421101 Input Buffer Cnvr. Overtime
P.C.B. from inp. Machine was not received.
Please continue the work after checking the P.C.B on a conveyor.
421102 Input Buffer Cnvr. Overtime
The P.C.B. transport (exhaust) to Cnvr. Positioning1 did not end in prescribed
time.
Please continue the work after checking the P.C.B on a conveyor.
421103 Input Buffer Cnvr. Overtime
The movement to P.C.B. receiving position did not end in prescribed time.
-----
421104 Input Buffer Cnvr. Overtime
The movement to the arrangement position did not end in prescribed time.
-----
421105 Input Buffer Cnvr. Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
421106 Input Buffer Cnvr. Overtime
The conveyor upper cover by input side has opened.
Please close the cover. Production can be continued.
421201 Input Buffer Cnvr. P.C.B. Detection
P.C.B.'s were at inlet and outlet of cnvr.
-----
421202 Input Buffer Cnvr. P.C.B. Detection
There is no P.C.B. on the conveyer. The P.C.B. fell while moving to the
arrangement position.
Please continue production after checking whether the P.C.B has fallen around a
conveyor.
421203 Input Buffer Cnvr. P.C.B. Detection
There is a P.C.B. on the conveyer. The substrate was not able to be exhausted.
Please continue the work after checking the P.C.B on a conveyor.
421204 Input Buffer Cnvr. P.C.B. Detection
There is no P.C.B on the conveyer. After the P.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
421205 Input Buffer Cnvr. P.C.B. Detection
Positioning change operation when beginning to be operated, the P.C.B was
detected with the entrance sensor.
Please remove the P.C.B of a conveyor entrance.
421206 Input Buffer Cnvr. P.C.B. Detection
The P.C.B was detected by the entrance sensor with the P.C.B was not able to be
transferred.
Please remove the P.C.B of a conveyor entrance.
421207 Input Buffer Cnvr. P.C.B. Detection
The P.C.B was detected with the conveyer exit sensor.
Please continue the work after checking the P.C.B on a conveyor.
3-150709-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421208 Input Buffer Cnvr. P.C.B. Detection
Manual bypass of the P.C.B was carried out in the state where a P.C.B is on a
conveyor.
Please remove the P.C.B carried out by manual bypass. Production can be
continued.
421209 Input Buffer Cnvr. P.C.B. Detection
The P.C.B was not found in the proper position.
Please remove the P.C.B on a conveyor. Production can be continued.
421210 Input Buffer Cnvr. P.C.B. Detection
Manual bypass of the P.C.B which is not a P.C.B transfer position can not be
done.
Please close the cover. Production can be continued.
421211 Input Buffer Cnvr. P.C.B. Detection
The P.C.B on a conveyor was removed.
Please close the cover. Production can be continued.
421212 Input Buffer Cnvr. P.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
421213 Input Buffer Cnvr. P.C.B. Detection
A P.C.B. was detected with the conveyor entrance sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
421214 Input Buffer Cnvr. P.C.B. Detection
A P.C.B. was detected with the conveyor exit sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
421215 Input Buffer Cnvr. P.C.B. Detection
A P.C.B. was detected with the both sensors of the conveyor entrance and exit
upon completion of the output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
421301 Input Buffer Cnvr. Error
The carrying in operation was not able to begin.
-----
421302 Input Buffer Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor.