3-34 0709-001 3.7 Automatic Setup Erroe ID Error Name, Description, Cause, and Remedy 49061c Conveyor Width Automatic Adjustment Head Up/Down Axis Zeroing Error . ----- 49061d Conveyor Width Automatic Adjustment The P .C…

100%1 / 271
3-33
3.7 Automatic Setup
0709-001
Erroe ID Error Name, Description, Cause, and Remedy
49060e Conveyor Width Automatic Adjustment
The L2 axis was not zeroed successfully.
-----
49060f Conveyor Width Automatic Adjustment
The BPC axis was not zeroed successfully.
-----
490610 Conveyor Width Automatic Adjustment
The current position of the X1 axis is not managed because the axis is not zeroed.
-----
490611 Conveyor Width Automatic Adjustment
The current position of the X2 axis is not managed because the axis is not zeroed.
-----
490612 Conveyor Width Automatic Adjustment
The current position of the Y axis is not managed because the axis is not zeroed.
-----
490613 Conveyor Width Automatic Adjustment
The escape operation of the X axis ended in an error condition.
-----
490614 Conveyor Width Automatic Adjustment
The escape operation of the Y axis ended in an error condition.
-----
490615 Conveyor Width Automatic Adjustment
The support pins could not ascend because the maximum conveyor width was not
obtained.
-----
490616 Conveyor Width Automatic Adjustment
The current P.C.B. width was not obtained because the pattern program data is
not
dened.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490618 Conveyor Width Automatic Adjustment
There is a P.C.B. on the conveyor
-----
490619 Conveyor Width Automatic Adjustment
Failed in Program Change Operation(Data Error).
-----
49061a Conveyor Width Automatic
Adjustment
Failed in Program Change Operation(Time out).
-----
49061b Conveyor Width Automatic Adjustment
Backup Base zeroing Error.
-----
3-340709-001
3.7 Automatic Setup
Erroe ID Error Name, Description, Cause, and Remedy
49061c Conveyor Width Automatic Adjustment
Head Up/Down Axis Zeroing Error.
-----
49061d Conveyor Width Automatic Adjustment
The P.C.B was detected on the Input conveyor.
Please remove the P.C.B on a Input conveyor.
49061e Conveyor Width Automatic Adjustment
The P.C.B was detected on the Cnvr. Positioning1.
Please remove the P.C.B on a Cnvr. Positioning1.
490621 Conveyor Width Automatic Adjustment
The P.C.B was detected on the Output conveyor.
Please remove the P.C.B on a Output conveyor.
490690 Conveyor Width Automatic Adjustment
Auto Setup Error(Others).
-----
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There
isnooatgoingupofa
nozzle,orpleasecheckwhetherthereisany
connection etc. in opening and closing.
490704 Nozzle set up
Nozzle Stocker up/dowon failed.
Thereisnooatgoingupofa
nozzle,orpleasecheckwhetherthereisany
connection etc. in opening and closing.
490705 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle
is placed.
Please check whether there is any difference in stocker arrangement data and
real arrangement.
490706 Nozzle set up
Headnozzleexistenceconrmationhaserror.
Please check whether there is any difference in head arrangement data and real
arrangement.
3-35
3.7 Automatic Setup
0709-001
Erroe ID Error Name, Description, Cause, and Remedy
490707 Nozzle set up
Thereisnofreespacefornozzlestoring.
Pleaseconrmthearrangementdata.
PleaseconrmtheStockerarrangementdata.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
PleasesetupaninsufcientnozzleinNoz
stocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
PleaseconrmthenozzlearrangementandtheStocker
arrangementdata.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Noz stocker position again on the instruction screen.
49070b Nozzle set up
Placement Hd / Noz data is not corresponding to the real arrangement.
Pleaseconrmtherealarrangementofthehead
nozzlearrangementdataand
the head.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
andconrmthereisnounexpectedvalue.
49070d Nozzle set up
It
failedinthenozzleplacementcheck.Conrm
therecognitionimageandselect
the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Pleaseconrmthenozzlehasnotadheredto
theposition.Moreover,please
clean the linear measure when not adhering.
49070f Nozzle set up
The placed nozzle was undetectable on the head otherwise, the nozzle was not
placed correctly or dust was detected.
Pleaseconrmwhetherthenozzlehasadheredto
theposition.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Pleaseconrmwhetherthenozzlehasadheredto
theposition.
490711 Nozzle set up
The remains nozzle was detected on the head.
Pleaseconrmthenozzlehasnotadheredto
theposition.Moreover,please
clean the linear measure when not adhering.
490712 Nozzle set up
The linear measure error occurred in the head nozzle existence check.
Pleaseconrmthenozzlearrangement,andexecutethe
levelteaching.