3-10 0802-002 3. Error IDs and Remedial Procedures Erroe ID Error Name, Description, Cause, and Remedy 400c01 Nozzle stocker down time out Nozzle stock unit lower bound detection 1 was not turned on in prescribed time. P…

100%1 / 271
3-90802-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400902 Tray Interlock Error
-----
400903 Tray Interlock Error
-----
400904 Tray Interlock Error
-----
400905 Tray Interlock Error
-----
400a01 Head Interlock Error
Head excess pushing detection 3[B05]
-----
400a02 Head Interlock Error
Head excess pushing detection 2[B05]
-----
400a03 Head Interlock Error
Head excess pushing detection 1[B05]
-----
400a04 Head Interlock Error
Pass line detection 3[B04]
-----
400a05 Head Interlock Error
Pass line detection 2[B04]
-----
400a06 Head Interlock Error
Pass line detection 1[B04]
-----
400a07 Head Interlock Error
Head Stop
-----
400a08 Head Interlock Error
Releasing the brake is impossible during Servo On.
-----
400a09 Head Interlock Error
Nozzle tilting detection 1[B1611]
Please
conrmthenozzleintheNozzleStocker
1.
400a0a Head Interlock Error
Nozzle tilting detection 2[B1611]
PleaseconrmthenozzleintheNozzleStocker
2.
400b01 Feeder preparation complete
A wrong setting of the suppressor or disengaged Latch was detected. [DA-B0510]
Openthesafetycoverandconrmthatthere
isnointerferencewiththehead,and
then, release the ready feeder.
3-100802-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400c01 Nozzle stocker down time out
Nozzle stock unit lower bound detection 1 was not turned on in prescribed time.
Pleaseconrmthelowerbounddetection1sensor
ofnozzlestockunit.
400c02 Nozzle stocker down time out
Nozzle stock unit lower bound detection 2 was not turned on in prescribed time.
Pleaseconrmthelowerbounddetection2sensor
ofnozzlestockunit.
400d01 Software Interlock Error
Head (rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.
400d02 Software Interlock Error
Head (rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.
3-110709-001
3.2 Data
3.2 Data
Table 4C4
Erroe ID Error Name, Description, Cause, and Remedy
410101 Data Error
Machine data and system data error detected.
-----
410102 Data Error
Auto run start mode setup data error
-----
410103 Data Error
Steps in converted pattern program is more
-----
410104 Data Error
Pattern Program Errors(P.E.C.Recog step error)
-----
410105 Data Error
The component library data used by the pattern program data doesn't exist.
-----
410106 Data Error
The nozzle type data registered in the nozzle data doesn't exist
-----
410107 Data Error
The nozzle type data registered in the nozzle data doesn't exist
-----
410201 Mode data Error
Abnormality is found in the production driving beginning mode setting data.
-----
410301 Pattern Program Error
Steps in converted pattern program is more
-----
410302 Pattern Program Error
There are Errors in converted pattern program(P.E..C. recog steps Error.)
-----
410303 Pattern Program Error
The converted pattern program is not exist, the data is damaged.
-----
410304 Pattern Program Error
The error is found in the adsorption nozzle number of the conversion pattern
program.
-----
410305 Pattern Program Error
The error is found in the order of adsorption of the conversion system pattern
program.
-----