3-23 3.3 Conveyor 0709-001 Erroe ID Error Name, Description, Cause, and Remedy 425218 Output Cnvr . P .C.B. Detection A P .C.B. was detected with the conveyor exit sensor upon completion of the output operation. After ch…

100%1 / 271
3-22
3.3 Conveyor
0709-001
Erroe ID Error Name, Description, Cause, and Remedy
425207 Output Cnvr. P.C.B. Detection
The P.C.B. was detected with the conveyer exit sensor.
PleaseconrmtheP.C.Bontheconveyer.
425208
Output Cnvr. P.C.B. Detection
The exhaust end board sensor of a conveyor exit detected the P.C.B.
Please check the P.C.B on a conveyor.
425209 Output Cnvr. P.C.B. Detection
The exhaust end board sensor of a conveyor exit did not detect P.C.B during
discharge operation.
Please check the sensor.
425210 Output Cnvr. P.C.B. Detection
Manual bypass of the P.C.B was carried out in the state where a P.C.B is on a
conveyor.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
425211 Output Cnvr. P.C.B. Detection
The P.C.B was not found in the proper position.
Please remove the P.C.B on a conveyor. Production can be continued.
425212 Output Cnvr. P.C.B. Detection
Manual bypass of the P.C.B was carried out.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
425213 Output Cnvr. P.C.B. Detection
P.C.B on a conveyer was removed in output sync / alternation output process.
Please do reproduction after making the P.C.B return to original state.
425214 Output Cnvr. P.C.B. Detection
The state of a P.C.B on conveyer changed in output sync / alternation output
process.
Please do reproduction after making the P.C.B return to original state.
425215 Output Cnvr. P.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
425216 Output Cnvr. P.C.B. Detection
The P.C.B. was detected before carrying-in operation.
Restart the product operation after removing the P.C.B. when it is on the
conveyor.
425217 Output Cnvr. P.C.B. Detection
A P.C.B. was detected with the conveyor entrance sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
3-23
3.3 Conveyor
0709-001
Erroe ID Error Name, Description, Cause, and Remedy
425218 Output Cnvr. P.C.B. Detection
A P.C.B. was detected with the conveyor exit sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425219 Output Cnvr. P.C.B. Detection
A P.C.B. was detected with the both sensors of the conveyor entrance and exit
upon completion of the output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
425220 Output Cnvr. P.C.B. Detection
The machine let the END P.C.B. remove from the conveyor.
Put the P.C.B. on the output conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
425301 Output Cnvr. Error
The carrying in operation was not able to begin.
-----
425302 Output Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor.
425303 Output Cnvr. Error
The exhaust operation was not able to begin.
-----
425304 Output Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
425305 Output Cnvr. Error
The P.C.B. transport to receiving position was not able to begin.
-----
425306 Output Cnvr. Error
The error was detected while transpoting to the receiving position.
-----
425307 Output Cnvr. Error
The operation moving to the arrangement position was not able to begin.
-----
425308 Output Cnvr. Error
The error was detected while transporting to the arrangement position.
-----
425309 Output Cnvr. Error
The reversal positioning operation was not able to begin.
-----
3-24
3.3 Conveyor
0802-002
Erroe ID Error Name, Description, Cause, and Remedy
425310 Output Cnvr. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
425311 Output Cnvr. Error
Conveyor width The conveyor upper cover by output side opened during axial
operation.
Please close a cover and perform again.
425312 Output Cnvr. Error
The conveyor upper cover by output side opened during production operation and
equipment operation.
Please close a cover and perform again.
425313 Output Cnvr. Error
The Output conveyor upper cover opened during production operation and
equipment operation.
Please close a cover and perform again.
425314 Output Cnvr. Error
It changed into the conveyor operation forbidden state during axial operation of
conveyor width. (The conveyor operation forbidden signal from output conveyor
was detected.)
Please cancel the forbidden operation state of a conveyor and perform again.
425315 Output Cnvr. Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught.
Pleaseconrmitoveraconveyer.
425316 Output Cnvr
. Error
Abnormality occurred at the time of disposal of Board END signals.
Please start production again.
425317 Output Cnvr. Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
425318 Output Cnvr. Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
426101 Input Conveyor Error
The initialization is imperfect.
-----
426102 Input Conveyor Error
An error occurred during zeroing operation.
Try to operate the zero return again.
426103 Input Conveyor Error
An alarm for interference is occurring.
-----