4OM-1431-006_w.pdf - 第166页

3-9 0802-002 3. Error IDs and Remedial Procedures Erroe ID Error Name, Description, Cause, and Remedy 400902 T ray Interlock Error ----- 400903 T ray Interlock Error ----- 400904 T ray Interlock Error ----- 400905 T ray …

100%1 / 271
3-80802-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400706 Zero Return
The Basis Mark recognition processing at the time of a beam XY (rear) starting
zeroed was not completed within predetermined time.
-----
400707 Zero Return
The Basis Mark recognition processing at the time of a beam XY (front) starting
zeroed was not completed within predetermined time.
-----
400801 Cutter Error
Cutter Alarm Detected(waveform Data setting)
-----
400802 Cutter Error
Cutter Alarm Detected(Zeroing)
-----
400803 Cutter Error
Cutter axis Time Out(Start zero)
-----
400804 Cutter Error
Cutter axis Time Out(Zero)
-----
400805 Cutter Error
Cutter
axiszeronished
-----
400806 Cutter Error
Cutter axis Alarm Detection(Start Locating)
-----
400836 Cutter Error
Cutter axis Time Out(when locating)
-----
400837 Cutter Error
Cutter axis Alarm Detected(During Locating)
-----
400838 Cutter Error
Cutter axis
Alarm Detected(During Locating). The cutter axis zeroing was carried
out.
Please check whether there are any errors in a cutter unit.
400839 Cutter Error
Because main circuit of the cutter axis was OFF or the servo was OFF. The feeder
base descent operation was not able to be done.
Please
conrmtheemergencystopandthesafety
door.
400901 Tray Interlock Error
Main Power Off
-----
3-90802-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400902 Tray Interlock Error
-----
400903 Tray Interlock Error
-----
400904 Tray Interlock Error
-----
400905 Tray Interlock Error
-----
400a01 Head Interlock Error
Head excess pushing detection 3[B05]
-----
400a02 Head Interlock Error
Head excess pushing detection 2[B05]
-----
400a03 Head Interlock Error
Head excess pushing detection 1[B05]
-----
400a04 Head Interlock Error
Pass line detection 3[B04]
-----
400a05 Head Interlock Error
Pass line detection 2[B04]
-----
400a06 Head Interlock Error
Pass line detection 1[B04]
-----
400a07 Head Interlock Error
Head Stop
-----
400a08 Head Interlock Error
Releasing the brake is impossible during Servo On.
-----
400a09 Head Interlock Error
Nozzle tilting detection 1[B1611]
Please
conrmthenozzleintheNozzleStocker
1.
400a0a Head Interlock Error
Nozzle tilting detection 2[B1611]
PleaseconrmthenozzleintheNozzleStocker
2.
400b01 Feeder preparation complete
A wrong setting of the suppressor or disengaged Latch was detected. [DA-B0510]
Openthesafetycoverandconrmthatthere
isnointerferencewiththehead,and
then, release the ready feeder.
3-100802-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400c01 Nozzle stocker down time out
Nozzle stock unit lower bound detection 1 was not turned on in prescribed time.
Pleaseconrmthelowerbounddetection1sensor
ofnozzlestockunit.
400c02 Nozzle stocker down time out
Nozzle stock unit lower bound detection 2 was not turned on in prescribed time.
Pleaseconrmthelowerbounddetection2sensor
ofnozzlestockunit.
400d01 Software Interlock Error
Head (rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.
400d02 Software Interlock Error
Head (rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.