1-41 3.3.10 Conveyor Section Conveyor Belt Shafts (3 places) Every 3 Months Cleaning and Lubrication (MOL YNOC GREASE AP1) Required T ime: 3 minutes W ipe off the old grease with a rag and apply new one with a brush. T a…

100%1 / 271
1-40
3.3.9 PCB Positioning Section
Upper Surface of Backup Table
Every Week Cleaning
Required Time: 1 minutes
Remove foreign substances and unrequired
components and suck dirt and dust with a
vacuum cleaner.
Ball Screws
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Wipe off old grease with a rag and apply
new one with a syringe.
Take ample care not to leave any
waste threads after cleaning.
Grease should be applied every 3 months
after the initial month.
Use No. 19 (brown) nozzle.
Notice
Note
No. 19
Ball Screw Splines
(Grease Nipple 3 places)
Every 6 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
(1) Wipe off old grease with an oiled rag.
Take ample care not to leave
any waste threads after
cleaning.
(2) Attach the H-type attachments to
a hand grease gun and supply new
grease to the grease nipples with the
hand grease gun.
Notice
Type H
Fig. 4A30
3.3 Inspection, Cleaning, and Lubrication Spots
0709-001
1-41
3.3.10 Conveyor Section
Conveyor Belt Shafts (3 places)
Every 3 Months Cleaning and Lubrication
(MOLYNOC GREASE AP1)
Required Time: 3 minutes
Wipe off the old grease with a rag and apply
new one with a brush.
Take ample care not to leave
any waste threads after cleaning.
Notice
Linear Guides (6 places)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 3 minutes
Wipe off old grease with a rag and apply
new one with a syringe.
Take ample care not to leave any
waste threads after cleaning.
Grease should be applied every 3 months
after the initial month.
Use No. 19 (brown) nozzle.
Notice
Note
No. 19
Fig. 4A31
3.3 Inspection, Cleaning, and Lubrication Spots
0709-001
1-42
PCB Detection Sensors (8 places)
Every Week Cleaning
Required Time: 2 minutes
Clean the PCB detection sensors with a
rag.
Support Pin Detection Sensors (4 places)
Every Week Cleaning
Required Time: 1 minute
Clean the support pin detection sensors with
a rag.
Fig. 4A32
3.3 Inspection, Cleaning, and Lubrication Spots
0709-001