4OM-1431-006_w.pdf - 第150页

2-19 0709-001 3.2 List of Machine Information Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 801a01 W arning Operation Product started by RUN MOD…

100%1 / 271
2-180709-001
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801708 Teach Nozzle Bypass
Dummy Nozzle.
801709 Teach Nozzle Bypass
Manual Bypass.
80170a Teach Nozzle Bypass
Nozzle Change Error.(Cam lock action)
80170b Teach Nozzle Bypass
Nozzle Change Error.(Cam Free action)
80170c Teach Nozzle Bypass
Cam Origin Error.
80170d Teach Nozzle Bypass
Nozzle Teach Error.
80170e Teach Nozzle Bypass
Nozzle Posture Detection
801801 Teach Head Bypass
Communication Error.
801802 Teach Head Bypass
Head Origin.
801803 Teach Head Bypass
Overtime Head Origin Return.
801804 Teach Head Bypass
Unselected Nozzle Drop.
801805 Teach Head Bypass
Dummy Nozzle.
801806 Teach Head Bypass
Manual Bypass.
801807 Teach Head Bypass
Alarm Error.
801901 Nozzle Adjustment
Nozzle up&down action is not available.
801902 Nozzle Adjustment
Communication error.
2-190709-001
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801a01 Warning Operation
Product started by RUN MODE "PASS"Operation.
801a02 Warning Operation
The P.C.B. before component placing was conveyed from X/Y table.
801a03 Warning Operation
The P.C.B. in the middle of component placing was conveyed from X/Y table.
801a04 Warning Operation
The feeder ready button was turned on in start protection mode.
801a05 Warning Operation
Cannot alternate by external start protection.
801b01 Lightning Surge Warning
Lightning Surge Protector works; Q204.
801b02 Lightning Surge Warning
Lightning Surge Protector works; Q204. Running continue.
801c01 Information
This placement step was detected outside of the possible range. This step is auto
skip running.
801c02 Information
Feeder carriage has been paused to avoid clash with missing component. Please
collect component before operating the feeder carriage.
801c03 Information
Data
waschangedduringmachineworked.Thechanged
dataisnotreectedin
operation until it stops or interrupts operation.
801c04 Information
PCB Origin Position data is not right. Please correct a PCB Origin Position on a
"Prod Chng(Origin Pos)" screen.
801c05 Information
Warm start mode was canceled.
801c06 Information
The machine stopped by the automatic stop function.
801c07 Information
Warm start mode was canceled. Please remove the unaccomplished P.C.B.
801c08 Information
It started with the data out of the setting range contained in the feeder offset B
data of system data. On edit screen, X/Y of the components (tape width 8mm /
sending pitch 2mm) should be set as more than -1.0mm and less than+1.0mm.
801c09 Information
It started with the data out of the setting range contained in the placement level
data of component supply changed data. On edit screen, the place level of square
shape below 3216 should be set up less than +0.5mm. When the place level
exceeding 0.5mm is required, please input H data of placement data (PP data).
2-200802-002
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801d01 Semi-auto(continue) start mode auto change
Production operation was interrupted for the state where PCB before component
are placed exists on XY table.
801e01 Placement Level Data
Calculated data out of range. Please check library data and pattern program data.
801f01 Warm start mode auto change
Operation was canceled for the state where the P.C.B. in the middle of component
placing is on X/Y table.
802001 Alarm for Splicing
Few components to feed. Please prepare Splicing.
802101 Feeder Maintenance Warning
The total number of feeder's shots reached a previous notice setting number.
802102 Feeder Maintenance Warning
The feeder adsorption rate decreased and exceeded the previous notice setting
number.
803001 FAN Stop Warning
The ceiling cooling fan stopped.
803003 FAN Stop Warning
The lower mount (left rear) cooling fan stopped.(M106)
803008 FAN Stop Warning
The CPU2 control box (left) cooling fan stopped.(M111)
803009 FAN Stop Warning
Fan stop detection satellite [STLT_FAN_MON] It does not answer. A fan stop is
normally undetectable.
80300a FAN Stop Warning
The
conveyormulti-axisamplier(left)coolingfanstopped.(M122)
80300e
FAN Stop Warning
The electrical system box power supply cooling fan (left) stopped.(M119)
80301a FAN Stop Warning
The ceiling (rear) cooling fan stopped.(M101)
80301b FAN Stop Warning
The ceiling (front) cooling fan stopped.(M102)
804001 WarningofSpeciedTestMode
"Enable" is set for the [Backup Base Axis Aging] in the Test Mode. Be sure to
check that there is no backup pin and jig under the chute because the backup
base will move up and down.
809001 Internal Exception Notice
CPU2 V
ector 0 exception has been disregarded.
809002 Internal Exception Notice
CPU2 spurious exception has been disregarded.
809003 Internal Exception Notice
CPU2undenedexceptionhasbeendisregarded.
809004 Internal Exception Notice
CPU3undened
exceptionhasbeendisregarded.