4OM-1431-006_w.pdf - 第174页

3-17 0709-001 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 421316 Input Buffer Cnvr . Error The P .C.B was transported a predetermined distance, but the operation was not completed. There is a possibi…

100%1 / 271
3-16
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421303 Input Buffer Cnvr. Error
The exhaust operation was not able to begin.
-----
421304 Input Buffer Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
421305 Input Buffer Cnvr. Error
The P.C.B. transport to receiving position was not able to begin.
-----
421306 Input Buffer Cnvr. Error
The error was detected while transporting to the receiving position.
-----
421307 Input Buffer Cnvr. Error
The operation moving to the arrangement position was not able to begin.
-----
421308 Input Buffer Cnvr. Error
The error was detected while transporting to the arrangement position.
-----
421309 Input Buffer Cnvr. Error
The input machine work transfer signal was turned off before the completion of
PCB carrying-in operation.
Please continue the work after checking the P.C.B on a conveyor.
421310 Input Buffer Cnvr. Error
The reversal positioning operation was not able to begin.
-----
421311 Input Buffer Cnvr. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
421312 Input Buffer Cnvr. Error
Conveyor width The conveyor upper cover by input side opened during axial
operation.
Please close a cover and perform again.
421313 Input Buffer Cnvr. Error
The conveyor upper cover by input side opened during production operation and
equipment operation.
Please close a cover and perform again.
421314 Input Buffer Cnvr. Error
The Input conveyor upper cover opened during production operation and
equipment operation.
Please close a cover and perform again.
421315 Input Buffer Cnvr. Error
It changed into the conveyor operation forbidden state during axial operation of
conveyor width. (The conveyor operation forbidden signal from Input conveyor
was detected.)
Please cancel the forbidden operation state of a conveyor and perform again.
0709-001
3-170709-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421316 Input Buffer Cnvr. Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught.Pleaseconrmitoveraconveyer.
421317 Input Buf
fer Cnvr. Error
Barcodeinformationcannotbeacquireddenitely.
Please take out the P.C.B from a conveyer
, and acquire bar code information
again.
421318 Input Buffer Cnvr. Error
It detected a BoardAvailable signal in the state that a device cannot take in a P.C.B
from input.
Please get rid of the factor so that a BoardAvailable signal does not appear.
421319 Input Buffer Cnvr. Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
421320 Input Buffer Cnvr. Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
421321 Input Buffer Cnvr. Error
An error occurred during END P.C.B. transfer operation.
Put the P.C.B. on the input conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
422101 Cnvr. Positioning1 Overtime
P.C.B. from inp. buffer cnvr. was not received.
Please continue the work after checking the P.C.B on a conveyor.
422103 Cnvr. Positioning1 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
422104 Cnvr. Positioning1 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
422105 Cnvr. Positioning1 Overtime
The P.C.B. transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
422106 Cnvr. Positioning1 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
3-180802-002
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422107 Cnvr. Positioning1 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
422108 Cnvr. Positioning1 Overtime
The P.C.B. transfer operation could not be completed in time.
Please continue the work after checking the P.C.B on a conveyor.
422201 Cnvr. Positioning1 P.C.B. Detection
P.C.B.'s were at inlet and outlet of cnvr.
Please continue the work after checking the P.C.B on a conveyor.
422202 Cnvr. Positioning1 P.C.B. Detection
There is no P.C.B on the conveyer. After the P.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
422203 Cnvr. Positioning1 P.C.B. Detection
No P.C.B. on the cnvr. After positioning released, P.C.B could not be detected.
Please continue the work after checking the P.C.B on a conveyor.
422204 Cnvr. Positioning1 P.C.B. Detection
The conveyer entrance sensor detected P.C.B.
Please continue the work after checking the P.C.B on a conveyor.
422205 Cnvr. Positioning1 P.C.B. Detection
The P.C.B. that has not been positioned exists.
Please position the P.C.B.
422206 Cnvr. Positioning1 P.C.B. Detection
An unsuitable detected state of the sensor is being kept.
When you remove the factor which the sensor has detected and there is a
P.C.B in the way of carrying in, please return on input buffer cnvr. and resume
production by WarmStart.
422207 Cnvr. Positioning1 P.C.B. Detection
The P.C.B was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
422208 Cnvr. Positioning1 P.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
422301 Cnvr. Positioning1 Error
The carrying in operation was not able to begin.
-----
422302 Cnvr. Positioning1 Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor.
422303 Cnvr. Positioning1 Error
The exhaust operation was not able to begin.
-----