4OM-1431-006_w.pdf - 第117页
1-58 (7) Checktheoilllerportandwipeoldgreaseoutusinganapplicator . Nipple Fig 4A54-5 (8) Align the cutter unit with the origin position on the left. Move it to the origin position on the left. (9) Attach th…

1-57
(4) Remove two screws and detach the belt cover.
Belt Cover
Screw
Screw
Fig 4A54-2
(5) Remove four screws and detach the cover.
Screws
Covers
Fig 4A54-3
(6) Move the cutter unit to the right hand side.
Cutter Unit
Fig 4A54-4
4.5 Lubricating Procedure onto the Linear Guide Oil Filler Port
0811-002

1-58
(7) Checktheoilllerportandwipeoldgreaseoutusinganapplicator.
Nipple
Fig 4A54-5
(8) Align the cutter unit with the origin position on the left.
Move it to
the origin position on the left.
(9) Attach the cover and fasten the four set screws.
(10) Attach the tape guid and fasten the four set screws.
(11) Attach the lower cover.
(12) Attach the upper cover.
(13) Lubricate the other cutter units using the same procedure in Steps (1) to (12).
4.5 Lubricating Procedure onto the Linear Guide Oil Filler Port
0811-002

1-59
0811-002
4.6 Cleaning of Linear Measure Sensor
Periodically perform cleaning of the linear measure sensor to maintain
reliable and stable measurement of component thickness.
•
Clean the sensor every day.
•
Change cleaning frequency according to varying frequency of use and
environmental conditions.
Linear Measure Sensor
(Light Receiver)
Linear Measure Sensor
(Light Emitter)
Horizontal Direction
Conic Cap
Surface of Conic
Reflector
Linear Measure Sensor (Light Emitter)
Fig. 4A55
•
Whileyouarecleaningthe
lightemitter,thesurfaceoftheconicreector
must be cleaned softly and horizontally.
Notice
Cleaning it vertically may damage the conic cap.
When the conic cap is damaged, the component recognition might
not be made correctly.
CAUTION
The light emitter of the linear measure sensor is made of glass.
If the light emitter happens to be damaged, be sure to suck up
the fragments with a vacuum cleaner, etc.
Do not collect the fragments with your bare hands to protect
your hands from injuries.
4.6 Cleaning of Linear Measure Sensor