4OM-1431-006_w.pdf - 第148页

2-17 0709-001 3.2 List of Machine Information Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 801301 Pickup Position Feedback Feedback value out o…

100%1 / 271
2-160802-002
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
800D0D Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#3)
800D0E Maintenance Warning
Componentboxllupwarning.(noticecountover)
800D0F Maintenance Warning
I
twasthetimeofmaintenance.[Aux
unit]Pleaseperformcleaningofauxspin
drum.
800E01 Program Change Warning
Check the setup of machine.(program change completed)
800E02 Program Change Warning
Check the setup of machine.(Program change completed. Run Mode changed to
"PASS".)
801001 Auto Offset Teach Information
Tape pocket recog error(run continue)
801101 Nozzlediameterconrmation
The disagreement of the nozzle diameter was detected with the linear measure.
Thereisapossibilityofthe
linearmeasuredirtandthenozzledirt,pleaseconrm
whether a different nozzle has adhered.
801201 Stat Auto Head Recovery
Cpu Communication error occurred.(CPU2-CPU3)
801202 Stat Auto Head Recovery
Head cam origin return action not complete.(Not CAM ORIGIN position)
801203 Stat Auto Head Recovery
Head Driver communication is time out.(from cpu3 job)
801204 Stat Auto Head Recovery
Nozzle change action not complete.(cam lock action NG)
801205 Stat Auto Head Recovery
Head cam position return action not complete.
801206 Stat Auto Head Recovery
Nozzle change action not complete.(cam free action NG)
801207 Stat Auto Head Recovery
Nozzle change action not complete.(Not CAM ORIGIN position)
801208 Stat Auto Head Recovery
Unselected Nozzle Drop.
801209 Stat Auto Head Recovery
Component output error(Pickup error) is detected by nozzle level was position.
;Nozzle posture detection
80120a Stat Auto Head Recovery
The selected nozzle was not at position. ;Nozzle posture detection
80120b Stat Auto Head Recovery
Component output error(Others) is detected by nozzle level was position. ;Nozzle
posture detection
2-170709-001
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801301 Pickup Position Feedback
Feedback value out of range. Please check feeder.
801401 Data Check
Pickup Level Data(Calculated data) is out of range. Please check library data and
offset data.
801402 Data Check
Placement height Data(Calculated data) is out of range. Please check library data
and offset data.
801403 Data Check
The data out of the setting range is contained in the feeder offset B data of
system data. On edit screen, X/Y of the components (tape width 8mm / sending
pitch 2mm) should be set as more than -1.0mm and less than +1.0mm.
801404 Data Check
The data out of the setting range is contained in the placement level data of
component supply changed data. On edit screen, the place level of square shape
below 3216 should be set up less than +0.5mm. When the place level exceeding
0.5mm is required, please input H data of placement data (PP data).
801501 Feeder Index Position
Production operation was interrupted in the middle of feeder index operation.
Please check a position.
801502 Feeder Index Position
The feeder carriage was returned to the home position in the middle of feeder
index operation. Please check a feeder index position.
801601 Product Restart
Restart
productionwithsemi-auto(afterspeciedstep)mode.
801602 Product Restart
Restart production with warm start mode.
801603 Product Restart
Restart production with warm start mode. Machine will stop after placement
complete.
PleaseconrmPCBafterward.
801701 Teach Nozzle Bypass
Nozzle Down Error.(L)
801702 Teach Nozzle Bypass
Nozzle Down Error.(H)
801703
Teach Nozzle Bypass
Recognition Teach Error.
801704 Teach Nozzle Bypass
Teach Error Data.
801705 Teach Nozzle Bypass
Lighting Check.
801706 Teach Nozzle Bypass
Nozzle Level.
801707 Teach Nozzle Bypass
Nozzle Drop
2-180709-001
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801708 Teach Nozzle Bypass
Dummy Nozzle.
801709 Teach Nozzle Bypass
Manual Bypass.
80170a Teach Nozzle Bypass
Nozzle Change Error.(Cam lock action)
80170b Teach Nozzle Bypass
Nozzle Change Error.(Cam Free action)
80170c Teach Nozzle Bypass
Cam Origin Error.
80170d Teach Nozzle Bypass
Nozzle Teach Error.
80170e Teach Nozzle Bypass
Nozzle Posture Detection
801801 Teach Head Bypass
Communication Error.
801802 Teach Head Bypass
Head Origin.
801803 Teach Head Bypass
Overtime Head Origin Return.
801804 Teach Head Bypass
Unselected Nozzle Drop.
801805 Teach Head Bypass
Dummy Nozzle.
801806 Teach Head Bypass
Manual Bypass.
801807 Teach Head Bypass
Alarm Error.
801901 Nozzle Adjustment
Nozzle up&down action is not available.
801902 Nozzle Adjustment
Communication error.