4OM-1431-006_w.pdf - 第205页
3-48 Erroe ID Error Name, Description, Cause, and Remedy 4b2009 P .C.B Height Measurement Detected a curve more than permission values. (- direction) ----- 4b200a P .C.B Height Measurement Error of the result measured by…

3-47
Erroe ID Error Name, Description, Cause, and Remedy
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Opensafetycoverandconrmthecomponenton
P.C.B.Pleaseremoveitor
revise it
4b1901 Monoaxial zeroing is abnormal.
It detected abnormality during movement.
Please get rid of an abnormal factor
4b1a01 Process error
Failed in restoration of the Machine data.
Please execute restoration operation from NT again.
4b1a02 Process error
Failed in restoration of the Network data.
Pleaseconrmthenetworksetting.
4b1a03 Process error
Failed in data transfer.
Please reboot machine.
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003
P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
4b2004 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----
3.9 Others
0802-002

3-48
Erroe ID Error Name, Description, Cause, and Remedy
4b2009 P.C.B Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a P.C.B Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2011 P.C.B Height Measurement
Measurement time-out
-----
4b2081 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2083 P.C.B Height Measurement
Measurement time-out
-----
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please
conrmthecableofSSCnetwork.
4b2102 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82
channel1andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2103 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82channel2andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2104 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83channel1andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
3.9 Others
0802-002

3-49
Erroe ID Error Name, Description, Cause, and Remedy
4b2105 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83channel2andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2)
Checkwhetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2106 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U84channel1andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2)
Checkwhetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2107 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U84channel2andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2108 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U90channel1andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2109 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U90channel2andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2201 Illegal Operation
ThereisnoPatternprogramle.
-----
4b2301 Feeder (Servo Error)
Alarm Code:A0 - Internal Parameter Error (Breakdown of Control P.C.B.)
Please replace the feeder. (Do not disconnect the feeder in powering on,
otherwise it may cause the inside data broken.)
3.9 Others