3-47 Erroe ID Error Name, Description, Cause, and Remedy 4b1201 Press in error / Insertion error There is an error with the component pressed in or Insertion Opensafetycoverandconrmthecomponenton P .C.B.Please…

100%1 / 271
3-46
3.9 Others
0802-002
Erroe ID Error Name, Description, Cause, and Remedy
4b0d02 Serial Out Mode Error
Communication failed to Shtg. of Comp. Host.
-----
4b0d03 NozzleConrmationErrorbeforepickupcomp
Communication with the Shtg. of Comp. Host has error.
-----
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b0f01
Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of feeder adsorption.
-----
4b0f02 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of nozzle adsorption.
-----
4b1101 Conveyance aging
Abnormalities occurred during P.C.B conveyance axis aging.
Please
checkmotor,amplierandunusualcontents
ofservo.(NL-Laxis,NA-L
axis, NB-L axis, NC-L axis, NR-L axis).
4b1102 Conveyance aging
The timeout occurred in conveyance axis operation during P.C.B conveyance axis
aging.
Pleasecheckmotor,amplierandunusualcontents
ofservo.(NL-Laxis,NA-L
axis, NB-L axis, NC-L axis, NR-L axis).
4b1103 Conveyance aging
Abnormalities occurred during backup base axis aging.
Pleasecheckmotor,amplierandunusualcontents
ofservo.(NA-Baxis,NC-B
axis).
4b1104 Conveyance aging
The timeout occurred in backup base axis operation during backup base axis
aging.
Pleasecheckmotor,amplierandunusualcontents
ofservo.(NA-Baxis,NC-B
axis).
4b1105 Conveyance aging
Abnormalities occurred during Y arrangement shuttle axis aging.
Pleasecheckmotor,amplierandunusualcontents
ofservo.(NL-W1axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
4b1106 Conveyance aging
The timeout occurred in Y arrangement shuttle axis operation during Y
arrangement shuttle axis aging.
Pleasecheckmotor,amplierandunusualcontents
ofservo.(NL-W1axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
3-47
Erroe ID Error Name, Description, Cause, and Remedy
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Opensafetycoverandconrmthecomponenton
P.C.B.Pleaseremoveitor
revise it
4b1901 Monoaxial zeroing is abnormal.
It detected abnormality during movement.
Please get rid of an abnormal factor
4b1a01 Process error
Failed in restoration of the Machine data.
Please execute restoration operation from NT again.
4b1a02 Process error
Failed in restoration of the Network data.
Pleaseconrmthenetworksetting.
4b1a03 Process error
Failed in data transfer.
Please reboot machine.
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003
P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
4b2004 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----
3.9 Others
0802-002
3-48
Erroe ID Error Name, Description, Cause, and Remedy
4b2009 P.C.B Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a P.C.B Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2011 P.C.B Height Measurement
Measurement time-out
-----
4b2081 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2083 P.C.B Height Measurement
Measurement time-out
-----
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please
conrmthecableofSSCnetwork.
4b2102 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82
channel1andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2103 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82channel2andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
4b2104 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83channel1andamplier.
(1) Shut down the machine and check the connection between the position board
andamplier.
(2) Check
whetherornotthemulti-axisamplierisdamaged.
(3) Checkwhetherornottheservoampliersaredamaged.
3.9 Others