4OM-1431-006_w.pdf - 第215页
3-58 3.1 1 Automatic Operation Error 0802-002 Erroe ID Error Name, Description, Cause, and Remedy 51010f Auto Run Error Motor function set timeout Please push the [emergency stop] button and execute W arm Start. 5101 10 …

3-57
3.11 Automatic Operation Error
0802-002
3.11 Automatic Operation Error
Table 4C12
Erroe ID Error Name, Description, Cause, and Remedy
510101 Auto Run Error
API Error
Please push the [emergency stop] button and execute Warm Start.
510102 Auto Run Error
Other axis positioning timeout
Please push the [emergency stop] button and execute Warm Start.
510103 Auto Run Error
Motor start preprocess error
Please push the [emergency stop] button and execute Warm Start.
510104 Auto Run Error
Motor start preprocess check timeout
Please push the [emergency stop] button and execute Warm Start.
510105 Auto Run Error
Motor positioning error
Please push the [emergency stop] button and execute Warm Start.
510106 Auto Run Error
Motor positioning timeout
Please push the [emergency stop] button and execute Warm Start.
510107 Auto Run Error
Motor mode set error
Please push the [emergency stop] button and execute Warm Start.
510108 Auto Run Error
Motor mode set timeout
Please push the [emergency stop] button and execute Warm Start.
510109 Auto Run Error
Motor positioning data set error
Please push the [emergency stop] button and execute Warm Start.
51010a Auto Run Error
Motor positioning data set timeout
Please push the [emergency stop] button and execute Warm Start.
51010b Auto Run Error
Motor start condition error
Please push the [emergency stop] button and execute Warm Start.
51010c Auto Run Error
Motor start command error
Please push the [emergency stop] button and execute Warm Start.
51010d Auto Run Error
Motor start command timeout
Please push the [emergency stop] button and execute Warm Start.
51010e Auto Run Error
Motor function set error
Please push the [emergency stop] button and execute Warm Start.

3-58
3.11 Automatic Operation Error
0802-002
Erroe ID Error Name, Description, Cause, and Remedy
51010f Auto Run Error
Motor function set timeout
Please push the [emergency stop] button and execute Warm Start.
510110 Auto Run Error
Motor position data read error
Please push the [emergency stop] button and execute Warm Start.
510111 Auto Run Error
Please push the [emergency stop] button and execute Warm Start.
510201 Auto Run Error
Pattern program error
Please modify the pattern program.
510202 Auto Run Error
Component Library
Please modify the comp. Library.
510203 Auto Run Error
Operation Mode Error
-----
510204 Auto Run Error
The system setting data is abnormal.
-----
510301 Auto Run Error
JOB time-out during processing.
Please push the [emergency stop] button and return.
510302 Auto Run Error
JOB control Error
-----
510501 Auto Run Error
The recognition result response Error. (Before placement)
-----
510502 Auto Run Error
The recognition result response Error. (After placement)
-----
510601 Auto Run Error
Feeder Alarm
-----
510602 Auto Run Error
Feeder Error (Feed Timeout)
-----
510603 Auto Run Error
Pickup Error
-----
510701 Auto Run Error
-----

3-59
3.11 Automatic Operation Error
0802-001
Erroe ID Error Name, Description, Cause, and Remedy
510703 Auto Run Error
Head Mis-Pickup Detection
Please do the comp. discard operation
510801 Auto Run Error
Warm Start Error
Please position the P.C.B.
510901 Auto Run Error
Comp.Vertical
-----
510902 Auto Run Error
Comp.Missing(Sensor)
-----
510903 Auto Run Error
Comp.recog.Error
-----
510904 Auto Run Error
Comp. Missing(Recog.)
-----
510a01 Auto Run Error
Pocket recog Error
-----
510b01 Auto Run Error
Master bad mark detection is abnormal.
-----
510b02 Auto Run Error
Bad mark detection is abnormal.
-----