3-64 3.13 T est 0802-001 3.13 T est T able 4C14 Erroe ID Error Name, Description, Cause, and Remedy 610101 Comp Recog T est The nozzle type data doesn't exist. ----- 610102 Comp Recog T est ----- 610103 Comp Recog T…

3-63
3.12 Automatic Teaching
0802-001
Erroe ID Error Name, Description, Cause, and Remedy
601a01 Linear measure correction re-teach
The linear measure reading is abnormal.
Pleaseconrmwhetherthenozzlehasadheredto
theposition.
601a02 Linear measure correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Linear measure correction re-teach
Nozzle can not be detected.
-----
601a04 Linear measure correction re-teach
The linear measure control has an error.
-----
601a05 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R)
-----
601a06 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/NR)
-----
601a07 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R & E/NR detection error)
-----
601a08 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error:
Shortage of Samples)
-----
601a09 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Failed
in the generation of the correction formula.)
-----
601a0a Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Inside
accuracy check error)
-----
601b01 Automatic teaching
The nozzle is not installed.
Please install the nozzle.

3-64
3.13 Test
0802-001
3.13 Test
Table 4C14
Erroe ID Error Name, Description, Cause, and Remedy
610101 Comp Recog Test
The nozzle type data doesn't exist.
-----
610102 Comp Recog Test
-----
610103 Comp Recog Test
-----
610104 Comp Recog Test
-----
610105 Comp Recog Test
-----
610106 Comp Recog Test
-----
610107 Comp Recog Test
-----
610108 Comp Recog Test
-----
610109 Comp Recog Test
-----
610201 XY Beam Test
-----
610301 P.E.C Recog Test
-----
610401 P.E.C Recog Test
-----
610501 P.E.C Recog Test
-----

3-65
3.14 System Error
0802-001
3.14 System Error
Table 4C15
Erroe ID Error Name, Description, Cause, and Remedy
FE0101 Auto Control Error