4OM-1431-006_w.pdf - 第177页

3-20 0709-001 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 422318 Cnvr . Positioning1 Error The P .C.B was transported a predetermined distance, but the operation was not completed. There is a possibi…

100%1 / 271
3-190709-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422304 Cnvr. Positioning1 Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
422305 Cnvr. Positioning1 Error
The error was deected while the backup base was rising.
-----
422306 Cnvr. Positioning1 Error
The error was detected while the backup base was descending.
-----
422307 Cnvr. Positioning1 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.
422308 Cnvr. Positioning1 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper.
422309 Cnvr. Positioning1 Error
The positioning change operation was not able to begin.
-----
422310 Cnvr. Positioning1 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the P.C.B on a conveyor.
422311 Cnvr. Positioning1 Error
The reversal positioning operation was not able to begin.
-----
422312 Cnvr. Positioning1 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
422313 Cnvr. Positioning1 Error
Pickup of a P.C.B went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.
422314 Cnvr. Positioning1 Error
The pickup OFF of a P.C.B went wrong.
-----
422315 Cnvr. Positioning1 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
422316 Cnvr. Positioning1 Error
Rise operation of a reversal PCB stopper is not completed.
Please check a stopper.
422317 Cnvr. Positioning1 Error
Downward operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
3-200709-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422318 Cnvr. Positioning1 Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught.Pleaseconrmitoveraconveyer.
422319 Cnvr
. Positioning1 Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
422320 Cnvr. Positioning1 Error
The P.C.B. transfer operation could not start.
-----
422321 Cnvr. Positioning1 Error
An error was detected in transferring the P.C.B..
Please continue the work after checking the P.C.B on a conveyor.
422322 Cnvr. Positioning1 Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
422323 Cnvr. Positioning1 Error
A servo error was found in the movement that the backup base was rising. The
backup jig and pins may be left under the transfer rail.
Cancel the error and perform zeroing operation after that, open the cover to
remove the left backup jig and pins under the transfer rail. Perform the setup
operation again to set the backup jig and the pins to the proper positions.
422324 Cnvr. Positioning1 Error
Support pins /Jig were detected before the backup base starts to rise.
Remove the support pins / jig from the backup base. If the removing operation is
difcult,
performthefunctiontomovethesupport
pinchangingposition.
3-21
3.3 Conveyor
0709-001
Erroe ID Error Name, Description, Cause, and Remedy
425102 Output Cnvr. Overtime
The P.C.B. transport (exhaust) to output machine did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
425103 Output Cnvr. Overtime
The movement to P.C.B. receiving position did not end in prescribed time.
-----
425104 Output Cnvr. Overtime
The movement to the arrangement position did not end in prescribed time.
-----
425105 Output Cnvr. Overtime
The P.C.B. transport (carry in) from Cnvr. Positioning1 did not end in prescribed
time.
Please continue the work after checking the P.C.B on a conveyor.
425106 Output Cnvr. Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
425107 Output Cnvr. Overtime
The conveyor upper cover by output side has opened.
Please close the cover. Production can be continued.
425201 Output Cnvr. P.C.B. Detection
P.C.B.'s were at inlet and outlet of cnvr.
Please continue the work after checking the P.C.B on a conveyor.
425202 Output Cnvr. P.C.B. Detection
There is no P.C.B. on the Cnvr. The P.C.B. fell while moving to the receiving
position.
Please continue production after checking whether the P.C.B has fallen around a
conveyor.
425203 Output Cnvr. P.C.B. Detection
There is no P.C.B. on the Cnvr. The P.C.B. was removed.
-----
425204 Output Cnvr. P.C.B. Detection
There is a P.C.B. on the Cnvr. The P.C.B. could not be discharged.
Please continue the work after checking the P.C.B on a conveyor.
425205 Output Cnvr. P.C.B. Detection
There is no P.C.B on the conveyer. After the P.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
425206 Output Cnvr. P.C.B. Detection
The P.C.B. was detected by the conveyer entrance sensor.
Please continue the work after checking the P.C.B on a conveyor.