. Seite 19 © Siemens AG . . Änderungen vorbehalten SIPLACE Placement Systems C&P M 8000, M 10 000 : z-axis gauge shown below must be used alternative Attention: only C& P M 8000, M 10000 head Assembly Z-Axis only…

. Seite 18
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
¾ tighten the screws of belt fastener.
¾ mount the belt fastener in the same position on the belt as before. It is visible on the crush
marks.
¾ place the belt fastener on the toothed belt such in a way that the edges are on the teeth or on
the space.
¾ the single parts of belt fastener can be aligned with a 10 mm spanner.
Z-belt belt fastener
Assembly Z-Axis (continuing)
Check belt tension using belt tension meter:
C&P DLM head: 280 +- 10 Hz

. Seite 19
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
C&P M 8000, M 10 000: z-axis gauge shown below must be used
alternative
Attention: only C&P M 8000, M 10000 head
Assembly Z-Axis only M 8000, M 10000

. Seite 20
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
C&P M 8000 / M 10000
¾ loosen and remove the hexagon socket head screw (1.5 mm allen wrench) of
z-axis upper stop.
¾ place a 0.3 mm feeler gauge on the upper stop.
¾ push the z-axis stop in the direction of the belt fastener and tighten the screw of the
z-axis upper stop.
¾ remove the feeler gauge and the gauge for z-axis upper stop.
¾ check belt tension using belt tension meter:
belt tension: C&P head: M 8000 / M 10000 head: 190 +- 10 Hz
upper stop z-axis
Assembly Z-Axis only M 8000, M 10000