00193407-02 HWWS SIPLACE Machine Accuracy EN.pdf - 第92页

在线预览 00193407-02 HWWS SIPLACE Machine Accuracy EN.pdf PDF 文档。

100%1 / 138
6 Recalibration S15 / F3
BE-Camera
Recalibration of component camera 18x25 (type 9)
01/2003 Edition 2 Overview
31
2YHUYLHZ
Component cameras should be recalibrated from time to time using the gray standard nozzle S-
15/F3 with reference to these calibration instructions. 
The work must be carried out by an experienced and appropriately-trained service engineer. 
During calibration, individual digital photographs of the gray standard nozzle are taken "manually".
A false color image is then output via a monitor. The camera setting is then assessed with refer-
ence to the color distribution (described in greater detail below).
 5HTXLUHPHQWV
Only suitable for 19 x 25 mm (type 9) component cameras which can be found in SIPLACE S-
15 and F3 machines.
Calibration tool service box S-15/F3.
The screen must be in as-new condition - all colors must be present and there must be no burn-
in of the surfaces of the cathode-ray tubes.
The machine must be allowed to warm up for at least 30 minutes.
 &RQWHQWRIWKHFDOLEUDWLRQWRROVHUYLFHER[6)LWHPQR
Service instructions . . . . . . . . . . . . . . . . . . . 00193311-03
5 gray standard nozzles S-15/F3 . . . . . . . . . 00372927-01
1 adjusting screwdriver. . . . . . . . . . . . . . . . . 00320276-01
Thread lock paint, black protective sticker (for CCD gain potentiometer)
Yellow recalibration sticker
1 pair of cotton gloves, white
2 test cables X2. . . . . . . . . . . . . . . . . . . . . . 00367018-01
X3. . . . . . . . . . . . . . . . . . . . . . 00367019-01
2 test cable extensions . . . . . . . . . . . . . . . . . 00373441-01