00193407-02 HWWS SIPLACE Machine Accuracy EN.pdf - 第56页
© Siemens AG . . Änderungen vorbehalten SIPLACE Placement Systems type of measuring plate ¾ measuring plate and dummies must match number of measures dummy type ¾ related to machine type ¾ dummy and measuri ng plate must…

© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
Specification
specification limit
dummy type
(depends on machine tape)
¾ max.4,5mm size for 12 nozzle
head (2 contacts)
¾ (glass dummies for pick &
place head and 6 nozzle head
sigma
CM Controller – Measuring Project

© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
type of measuring plate
¾ measuring plate and dummies must
match
number of measures
dummy type
¾ related to machine type
¾ dummy and measuring plate must
match
number of placed dummies
distance dummy to dummy
offset to zero
angle
check box, if more than
one head is in use
Inspection plan: basic data
CM Controller – Measuring Project

© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
placement angle
placement angle, which is
used in the first row or column
fiducial for Layout data
Inspection plan: placement angle
CM Controller – Measuring Project