00193407-02 HWWS SIPLACE Machine Accuracy EN.pdf - 第41页
. Seite 5 © Siemens AG . . Änderungen vorbehalten SIPLACE Placement Systems Mapping Plates (Alu)

. Seite 4
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
Mapping Plates (Glass)
Attention:
For application on double transport, please turn Version 3 for 90 degree;
The arrows on the mapping plate indicate the direction.
Calibration of Mapping Plates
Mapping plates must be recalibrated every four years.
The date for the next recalibration is on the calibration certificate.
Please contact the SCC in Munich for detailed information.

. Seite 5
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
Mapping Plates (Alu)

. Seite 6
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
Preparation for Mapping
Menue ‘Mapping’
executes only the PCB mapping.
Menue ‘Mapping and Heads’
executes only the BCB mapping and RV mapping of C&P head, as also the IC-Mapping of TWIN-
head.
Calibration tools will be used in serial modus with one mapping plate or in parallel modus with two
or more Mapping plates.
min. 1 nozzle 956 is required at the C&P-head;
nozzle 517 is required on TWIN head
with starting PCB mapping, any corner at the mapping plate can be taught as reference corner.
from this corner as reference, a cross-type-fiducial is measured and in conjunction with another
fiducial on the other side, the angle offset of the mapping-plate is measured.