Exercise 1:
Calculate the Cm and Cmk value for a placement machine within a specification of 90 um at 4
Sigma with following indices:
standard distribution -18.5 um Cm value: ............................
offset - 21.0 um Cmk value: ...........................
Evaluate the result
Is the machine ... capable { not capable |
Exercise 2:
Calculate the Cm and Cmk value for the same placement machine within a specification of 135 um
at 6 sigma with following indices:
standard distribution -18.5 um Cm value: .............................
offset - 21.0 um Cmk value: .............................
Evaluate the result:
Is the machine ... capable { not capable |
Exercise 3:
Evaluate the results and compare it with the required specification
Exercise Maschine Capability
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
-
NOTES