00193407-02 HWWS SIPLACE Machine Accuracy EN.pdf - 第93页
Recalibration of component camera 18x25 (type 9) 01/2003 Edition 2 Overview 31 2YHUYLHZ Component c ameras should b e recal ibrated from time to t ime usin g the gray standard n ozzle S- 15/F3 wi th referenc e to the s…
Recalibration of component camera 18x25 (type 9)
01/2003 Edition 2 Overview
31
2YHUYLHZ
Component cameras should be recalibrated from time to time using the gray standard nozzle S-
15/F3 with reference to these calibration instructions.
The work must be carried out by an experienced and appropriately-trained service engineer.
During calibration, individual digital photographs of the gray standard nozzle are taken "manually".
A false color image is then output via a monitor. The camera setting is then assessed with refer-
ence to the color distribution (described in greater detail below).
5HTXLUHPHQWV
– Only suitable for 19 x 25 mm (type 9) component cameras which can be found in SIPLACE S-
15 and F3 machines.
– Calibration tool service box S-15/F3.
– The screen must be in as-new condition - all colors must be present and there must be no burn-
in of the surfaces of the cathode-ray tubes.
– The machine must be allowed to warm up for at least 30 minutes.
&RQWHQWRIWKHFDOLEUDWLRQWRROVHUYLFHER[6)LWHPQR
– Service instructions . . . . . . . . . . . . . . . . . . . 00193311-03
– 5 gray standard nozzles S-15/F3 . . . . . . . . . 00372927-01
– 1 adjusting screwdriver. . . . . . . . . . . . . . . . . 00320276-01
– Thread lock paint, black protective sticker (for CCD gain potentiometer)
– Yellow recalibration sticker
– 1 pair of cotton gloves, white
– 2 test cables X2. . . . . . . . . . . . . . . . . . . . . . 00367018-01
X3. . . . . . . . . . . . . . . . . . . . . . 00367019-01
– 2 test cable extensions . . . . . . . . . . . . . . . . . 00373441-01