00193407-02 HWWS SIPLACE Machine Accuracy EN.pdf - 第73页

© Siemens AG . . Änderungen vorbehalten SIPLACE Placement Systems -85.0 -70. 0 -55. 0 -40.0 -25. 0 -10. 0 5.0 15.0 30.0 45.0 60.0 75.0 90.0 x-offset [µm] 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 x-axis example 1: average…

100%1 / 138
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
x-direction
average value adjustment by use of a simple offset:
¾ single value diagram
0 5 10 15 20 25 30 35
number of placements
-80
-60
-40
-20
0
20
40
60
x-offset [µm]
single value diagram x-offset
x-axis
Average Value (shifted)
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
-85.0 -70.0 -55.0 -40.0 -25.0 -10.0 5.0 15.0 30.0 45.0 60.0 75.0 90.0
x-offset [µm]
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
x-axis
example 1: average value adjustment by use of a simple offset:
¾ frequency plot
Average Value (shifted)
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
-80 -60 -40 -20 0 20 40 60
x-offset [µm]
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
y-offset [µm]
X-Y-Diagramm Ausgangszustand
x-axis
y-axis
average value adjustment by use of a simple offset:
¾ x-y-plot
X-Y-diagram: placement 1
x-axis
Average Value (shifted)