© Siemens AG . . Änderungen vorbehalten SIPLACE Placement Systems With performing a trend analysis we can recognize mapping errors, e.g. as higher the y-coordinat e, as higher the deviation which trend is visible? ¾ offs…

© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
single value diagram final state: x-offset
0 20 40 60 80 100
number of
placements
-300
-250
-200
-150
-100
-50
0
50
100
150
200
250
x-Versatz [µm]
x-direction
irregularity???
0
90
180
270
Graph
Example 2: Offset at Placement Angle

© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
With performing a trend analysis we can recognize mapping errors,
e.g. as higher the y-coordinate, as higher the deviation
which trend is visible?
¾ offset increases with rising x-values (depending on the placement coordinate)
therefore required specification not achieved (C
m
-value).
Trend Analysis
Attention:
nevertheless, the average value can be in tolerance and a correction is normally not
possible by changing any software values.

© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
numerical evaluation
Trend Analysis