© Siemens AG . . Änderungen vorbehalten SIPLACE Placement Systems Dummy graphical evaluation: color atlas ¾ the trend is clear visible, differe nt color represent the deviation Y-offset single value diagram measurement _…

100%1 / 138
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
numerical measuring results
¾ average values
¾ standard deviation
¾ range
¾ capability values
Measurement Project in General
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
Dummy
graphical evaluation: color atlas
¾ the trend is clear visible, different color represent the deviation
Y-offset single value diagram measurement _01
Measurement Project in General
© Siemens AG . . Änderungen vorbehalten
SIPLACE
Placement Systems
0.00 25.00 50.00 75.00 100.00 125.00 150.00 175.00 200.00
-100
-80
-60
-40
-20
0
20
40
60
80
100
offset [µm]
single value diagram
placement 1: X-offset
cm = 1.99, cmk = 1.98
placement 1: Y-offset
cm = 1.94, cmk = 1.83
Regression line (best adjustment of a line to the measured values)
number of placement
X/Y-axis
graphical evaluation: color atlas
Measurement Project in General